Download Print this page

Conversion Instructions - PARRY PGG6 Instructions Manual

Gas griddle
Hide thumbs Also See for PGG6:

Advertisement

TELEPHONE:
SERVICE (44) 01332 875665
FAX:
SERVICE (44) 01332 875536

CONVERSION INSTRUCTIONS

This conversion must be carried out by a competent qualified person.
Natural to LPG
1. Remove fascia panel (2 screws underneath)
2. Remove fascia panel and disconnect ignition leads
3. Disconnect the gas feed at injector elbow.
4. Unscrew and remove aerator
5. Undo the back nut holding the injector elbow to the burner and remove
6. Remove natural injector and replace with the LPG injector issued
7. Re-assemble in the reverse order, refit the aerator.
8. Replace the existing labels and data plate with the LPG labels provided.
9. Low rate screw is on front L/H side of tap.
10. Low rate must be adjusted by inserting a small flat screwdriver and turning
clockwise to the stop. This must only be done by a qualified corgi
engineer, and as this setting has been factory sealed. Any alterations must
be resealed.
LPG to Natural
1. Remove fascia panel (2 screws underneath)
2. Remove fascia panel and disconnect ignition leads
3. Disconnect the gas feed at injector elbow.
4. Unscrew and remove aerator
5. Undo the back nut holding the injector elbow to the burner and remove
6. Remove LPG injector and replace with the natural injector issued
7. Re-assemble in the reverse order, refit the aerator.
8. Replace the existing labels and data plate with the natural labels
provided.
9. Low rate screw is on front L/H side of tap.
10. Low rate must be adjusted by inserting a small flat screwdriver and
turning clockwise to the stop. This must only be done by a qualified
corgi engineer, and as this setting has been factory sealed. Any
alterations must be resealed.
Model
Butane G30 @28mbar 11.2" W.G.
PGG6
Propane G31 @ 37mbar 14.8" W.G.
Nat Gas G20 @ 20mbar 8" W.G.
PGG6
Nat Gas G25 @ 25mbar 10" W.G.
Butane G30 @28mbar 11.2" W.G.
PGG7
Propane G31 @ 37mbar 14.8" W.G.
Nat Gas G20 @ 20mbar 8" W.G.
PGG7
Nat Gas G25 @ 25mbar 10" W.G.
Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT
INSTRUCTION REF: IN103
ISSUE NO. 6
DATE 19.10.11.
Page 10 of 17
www.parry.co.uk
Injector Code
INJECT082
INJECT130
INJECT099
INJECT150

Advertisement

loading

This manual is also suitable for:

Pgg7