Download Print this page

PARRY PGG6 Instructions Manual page 11

Gas griddle
Hide thumbs Also See for PGG6:

Advertisement

TELEPHONE:
SERVICE (44) 01332 875665
FAX:
SERVICE (44) 01332 875536
TECHNICAL DETAILS
MODEL PGG6 GRIDDLE
Per Burner (All figures are NET)
GAS
NATURAL G20
BUTANE
G30
PROPANE G31
G25
GAS RATE
M³/HR
NATURAL G20
0.254 M³/HR
BUTANE
G30
0.087 M³/HR
PROPANE G31
0.112 M³/HR
G25 @ 25mb
0.318 M³/HR
AIR FLOW RATE FOR
COMBUSTION 20m³/HR
Total Unit (All figures are NET)
GAS
NATURAL G20
BUTANE
G30
PROPANE G31
G25
GAS RATE
M³/HR
NATURAL G20
0.509 M³/HR
BUTANE
G30
0.174 M³/HR
PROPANE G31
0.223 M³/HR
G25 @ 25mb
0.636 M³/HR
AIR FLOW RATE FOR
COMBUSTION 20m³/HR
INJECTORS
Natural G20 = INJECT130
Butane G30 = INJECT082
Propane G31 = INJECT082
G25 @ 25mb = INJECT130
Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT
OPERATING PRESSURE
20mb/8"
W.G.
29mb/11.2" W.G.
37mb/14.8" W.G.
25mb/10"
W.G.
FT³/HR
8.970 FT³/HR
3.072 FT³/HR
3.938 FT³/HR
11.230 FT³/HR
3.18M³/HR
OPERATING PRESSURE
20mb/8"
W.G.
29mb/11.2" W.G.
37mb/14.8" W.G.
25mb/10"
W.G.
FT³/HR
17.975 FT³/HR
6.145 FT³/HR
7.875 FT³/HR
22.460 FT³/HR
6.36 M³/HR
www.parry.co.uk
INSTRUCTION REF: IN103
ISSUE NO. 6
DATE 19.10.11.
Page 11 of 17
TOTAL HEAT INPUT
2.400 KW = 8190Btu/h
2.806 KW = 9572Btu/h
2.726 KW = 9300 Btu/h
2.584 KW = 8816Btu/h
LB/HR
0.452 LB/HR 0.205 KG/HR
0.433 LB/HR 0.196 KG/HR
TOTAL HEAT INPUT
4.810 KW = 16412 Btu/h
5.611 KW = 19145 Btu/h
5.451 KW = 18599 Btu/h
5.168 KW = 17632 Btu/h
LB/HR
0.903 LB/HR 0.410 KG/HR
0.865 LB/HR 0.392 KG/HR
KG/HR
KG/HR

Advertisement

loading

This manual is also suitable for:

Pgg7