Download Print this page

PARRY PGG6 Instructions Manual

Gas griddle
Hide thumbs Also See for PGG6:

Advertisement

Quick Links

TELEPHONE:
SERVICE (44) 01332 875665
FAX:
SERVICE (44) 01332 875536
GAS GRIDDLE INSTRUCTIONS
MODEL NUMBER:
SERIAL NUMBER:
PURCHASE DATE:
DISTRIBUTOR:
Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT
MODEL: PGG6
MODEL: PGG7
VALIDATE WARRANTY
SAFETY INSTRUCTIONS
INSTALLATION INSTRUCTIONS
OPERATION INSTRUCTIONS
MAINTENANCE INSTRUCTIONS
CONVERSION INSTRUCTIONS
TECHNICAL DATA
PARTS LIST
SPARES LIST
WARRENTY INFORMATION
Customer Information
______________________
______________________
______________________
______________________
www.parry.co.uk
INSTRUCTION REF: IN103
ISSUE NO. 6
DATE 19.10.11.
Page 1 of 17

Advertisement

loading

Summary of Contents for PARRY PGG6

  • Page 1 INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION INSTRUCTIONS TECHNICAL DATA PARTS LIST SPARES LIST WARRENTY INFORMATION Customer Information ______________________ MODEL NUMBER: ______________________ SERIAL NUMBER: PURCHASE DATE: ______________________ ______________________ DISTRIBUTOR: Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
  • Page 2 PLEASE NOTE THAT FAILURE TO RETURN A WARRANTY CARD WILL RESULT IN PARRY BEING UNABLE TO SEND AN ENGINEER TO CARRY OUT WARRANTY WORK Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT...
  • Page 3: Safety Instructions

    NOT been removed. It is IMPORTANT that this protective film is peeled off before the equipment is used. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
  • Page 4 SEE TECHNICAL DETAILS. 5. Appliances are designed to be installed, and fitted on a Parry stand for stability. If they are fitted on any other surface they should be suitably secured.
  • Page 5 11. These appliances are to be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrates of substances harmful to health in the room in which they are installed. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
  • Page 6 To remove any residue use a scraper several times a day after cooking. Scaling will result if this is not done. Empty the fat drawer and clean every day. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
  • Page 7 MAINTENANCE INSTRUCTIONS MAINTENANCE AND SERVICE MUST ONLY BE UNDERTAKEN BY REGISTERED FITTERS. Parry advise that regular annual maintenance should be conducted by a Gas Safe registered engineer. This is essential to maintain safety and prolong life of the appliance. PLEASE NOTE THE LOW RATE ADJUSTER ON THE UNIT HAS BEEN...
  • Page 8 Refit the saddle bracket and tighten the two screws. Reconnect gas feed to injector and gas cock and tighten Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
  • Page 9 Refit thermocouple and tighten do not over tighten Refit thermostat phial to plate. Reconnect gas supply and soundness test Check flame failure device is operating Refit fascia and cooking plate. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
  • Page 10: Conversion Instructions

    Butane G30 @28mbar 11.2” W.G. PGG7 INJECT099 Propane G31 @ 37mbar 14.8” W.G. Nat Gas G20 @ 20mbar 8” W.G. PGG7 INJECT150 Nat Gas G25 @ 25mbar 10” W.G. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
  • Page 11 22.460 FT³/HR AIR FLOW RATE FOR 6.36 M³/HR COMBUSTION 20m³/HR INJECTORS Natural G20 = INJECT130 Butane G30 = INJECT082 Propane G31 = INJECT082 G25 @ 25mb = INJECT130 Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
  • Page 12 HT Cable CABLHT500 Piezo Sparker PIEZOISP1 Saddle Bracket BRACKET01 Gas Cock Knob KNOBPHEN Aerator AIRGRIDNG Flue Cover Low Rate Adjuster Injector PGG6 Natural INJECT130 Injector PGG6 LPG INJECT082 Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
  • Page 13 0.850 M³/HR 30.014 FT³/HR AIR FLOW RATE FOR 300.14FT³/HR COMBUSTION 20m³/HR INJECTORS Natural G20 = INJECT150 Butane G30 = INJECT099 Propane G31 = INJECT099 G25 @ 25mb = INJECT150 Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
  • Page 14 MBETCASSY HT Cable CABLHT500 Piezo Sparker PIEZOISP1 Saddle Bracket BRACKET01 Gas Cock Knob KNOBPHEN Aerator Flue Cover Low Rate Adjuster Injector PGG7 Natural INJECT150 Injector PGG7 LPG INJECT099 Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
  • Page 15 To place an spares order please contact our Official Spares Partners at First Choice Catering Spares LTD Contact them by telephone on 01543 577778 Or alternatively visit their website at http://www.firstchoice-cs.co.uk/ Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
  • Page 16  If the problem with the machine can not be resolved please contact the company that supplied you the machine. (SERVICE CALLS CAN NOT BE PLACED DIRECT WITH PARRY) Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
  • Page 17: Not Covered Under Warranty

    6 burner cooker.  Excessive carbon build up on griddle plates.  Over use of lava rock on the chargrills recommended use by Parry 2kg only.  Faulty electrics – eg, customers plug socket, plug, wiring, junction box fault, wrong fuse.

This manual is also suitable for:

Pgg7