Daikin FXAQ20PVE Installation Manual page 9

Vrv system
Table of Contents

Advertisement

< Replacing the drain hose and drain plug >
(1) Remove the drain plug and insulation tubing.
(2) Remove the drain hose and replace onto the left side.
(3) Replace the drain plug and the insulation tubing onto the right side.
Insulating tube
Make sure
there are
no gaps.
Fig. 8
(6) Hook the indoor unit onto the installation panel. (Refer to Fig. 9)
• Placing buffering material between the wall and the indoor unit at this time will make work easier.
Front panel
Be sure to pass all wires through
the wiring guide.
Refrigerant piping
Wiring (locally procured)
Power supply wiring, Transmission wiring, Earth wiring,
Remote controller wiring
For right, bottom-right, and back-right piping
• Pass the drain hose and the refrigerant piping to the wall.
(7) Pass power supply wiring, transmission wiring, earth wiring, and remote controller wiring through
the wiring guide in through the back of the indoor unit and to the front.
8
Drain plug
Do not place lubricant (refrigerant oil) when inserting.
This may cause deterioration and water leaks.
Insert using a hexagon wrench (4mm).
Service cover
Hook the indoor unit hook onto the installation panel (1).
Front grille
Tab
(There are 2 places.)
Place buffering material
Wall
Installation panel
(accessory) (1)
Fig. 9
English

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fxaq25pveFxaq32pveFxaq40pveFxaq50pveFxaq63pve

Table of Contents