Daikin FXAQ-MAVE9 Series Technical Data Manual
Daikin FXAQ-MAVE9 Series Technical Data Manual

Daikin FXAQ-MAVE9 Series Technical Data Manual

Wall mounted unit

Advertisement

technical data
Wall Mounted Unit
FXAQ-MAVE9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FXAQ-MAVE9 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin FXAQ-MAVE9 Series

  • Page 1 technical data Wall Mounted Unit FXAQ-MAVE9...
  • Page 2: Table Of Contents

    • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 TABLE OF CONTENTS FXAQ-MAVE9 ® Specifications ............2 Technical Specifications .
  • Page 3: Specifications

    • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Specifications ® U n i A V E o o r Q - M I n d F X A 1-1 TECHNICAL SPECIFICATIONS FXAQ20MAVE9 FXAQ25MAVE9 FXAQ32MAVE9 FXAQ40MAVE9 FXAQ50MAVE9 FXAQ63MAVE9 Capacity Cooling Heating Power Input (50Hz) Cooling...
  • Page 4: Electrical Specifications (50Hz)

    • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Specifications 1-2 ELECTRICAL SPECIFICATIONS (50HZ) FXAQ20MAVE9 FXAQ25MAVE9 FXAQ32MAVE9 FXAQ40MAVE9 FXAQ50MAVE9 FXAQ63MAVE9 Power Supply Name Phase Frequency Voltage 220-240 Current Minimum circuit amps (MCA) Maximum fuse amps (MFA) Full load amps (FLA) Voltage range Minimum -10%...
  • Page 5: Safety Device Settings

    • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Safety device settings FXAQ20MV FXAQ25MV FXAQ32MV FXAQ40MV FXAQ50MV FXAQ63MV PC BOARD FUSE 250V 3A 4D034906F Options FXAQ20MV FXAQ25MV FXAQ32MV FXAQ40MV FXAQ50MV FXAQ63MV DRAIN PUMP KIT K-KDU572CVE ED39-226B Control systems Individual control systems FXAQ20MV FXAQ25MV FXAQ32MV...
  • Page 6: Capacity Tables

    • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Capacity tables 5 - 1 Cooling capacity tables FXAQ-MV TC: Total capacity;kW – SHC: Sensible capacity;kW Indoor air temperature Outdoor Nominal 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB Unit size air temp. capacity 20.0DB 23.0DB...
  • Page 7 • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Capacity tables 5 - 1 Cooling capacity tables FXAQ-MV TC: Total capacity;kW – SHC: Sensible capacity;kW Indoor air temperature Outdoor Nominal 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB Unit size air temp. capacity 20.0DB 23.0DB...
  • Page 8: Heating Capacity Tables

    • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Capacity tables 5 - 2 Heating capacity tables FXAQ-MV Outdoor Indoor air temperature °CDB Unit Size Nominal capacity 16.0 18.0 20.0 21.0 22.0 24.0 air temperature °CDB °CWB -19.8 -20.0 -18.8 -19.0 -16.7 -17.0...
  • Page 9 • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Capacity tables 5 - 2 Heating capacity tables FXAQ-MV Outdoor Indoor air temperature °CDB Unit Size Nominal capacity 16.0 18.0 20.0 21.0 22.0 24.0 air temperature °CDB °CWB -19.8 -20.0 -18.8 -19.0 -16.7 -17.0...
  • Page 10: Dimensional Drawing & Centre Of Gravity

    • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FXAQ20,25,32MV Piping direction Approx. 400 Part name Description Dimensions for Front panel full open front panel Front grill Air outlet Gas pipe ø...
  • Page 11 • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FXAQ63MV Piping direction Approx. 400 Part name Description Front panel Front grill Air outlet Dimensions for full open front Gas pipe ø...
  • Page 12: Piping Diagram

    • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Piping diagram FXAQ-MV Heat exchanger Liquid pipe connection port Filter Filter Electronic Gas pipe connection port expansion valve Refrigerant flow Cooling Heating Piping connection diameters Model Liquid FXAQ20,25,32,40,50MV ø12.7 ø6.4 FXAQ63MV ø15.9 ø9.5 DU220-602J...
  • Page 13: Wiring Diagram

    • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Wiring diagram 8 - 1 Wiring diagram FXAQ-MV POWER SUPPLY Note: 5 Receiver/Display unit (Infrared remote control) Note: 5 Input from outside note 3 Transmission wiring Central remote control note 1 Side Wired remote control Front...
  • Page 14: Sound Data

    • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Sound data 9 - 1 Sound level data FXAQ-MV Sound pressure level Model Sound power level Measuring location FXAQ20MV FXAQ25MV FXAQ32MV FXAQ40MV FXAQ50MV Microphone FXAQ63MV NOTES Reference acoustic pressure 0 dB = 20 Pa. Measuring place: anechoic chamber.
  • Page 15: Sound Pressure Spectrum

    • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Sound data 9 - 2 Sound pressure spectrum FXAQ20MV 4D037087D FXAQ25MV 4D037088D Approximate Approximate treshold hearing for treshold hearing for continuous noise continuous noise Ocatve band center frequency (Hz) Ocatve band center frequency (Hz) NOTES NOTES Over all (dB):...
  • Page 16 • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Sound data 9 - 2 Sound pressure spectrum FXAQ50MV 4D038514A FXAQ63MV 4D038515A Approximate Approximate treshold hearing for treshold hearing for continuous noise continuous noise Ocatve band center frequency (Hz) Ocatve band center frequency (Hz) NOTES NOTES Over all (dB):...
  • Page 17: Installation

    • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Installation 10 - 1 Drainage instructions Install the drain piping • The drain pipe should be short with a downward slope and should prevent the formation of air pockets. Make sure the drain hose is at a Drain hose Drain hose downward slope.
  • Page 18: Service Space

    • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Installation 10 - 2 Service space 1 Select an installation site where the following conditions are fulfilled and that meets with your customer’s approval. • In the upper space (including the back of the ceiling) of the indoor unit where there is no possible dripping of water from the refrigerant pipe, drain pipe, water pipe, etc.
  • Page 19 • Indoor Units • Wall Mounted Unit • FXAQ-MAVE9 Installation 10 - 2 Service space ® • VRV Systems • Indoor Units...
  • Page 20 Specifications are subject to change without environment. This challenge demands the eco design prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or and development of a wide range of products and an indirect damage, in the broadest sense, arising from or related to the use energy management system, resulting in energy and/or interpretation of this publication.