EEDDE08-204

technical data

Wall Mounted Unit
FXAQ-MAVE
2e

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FXAQ-MAVE

  • Page 1: Technical Data

    EEDDE08-204 technical data Wall Mounted Unit FXAQ-MAVE...
  • Page 2: Table Of Contents

    • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE TABLE OF CONTENTS FXAQ-MAVE Specifications ............2 Technical Specifications .
  • Page 3: Specifications

    • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Specifications U n i t e m A V E o o r Q - M S y s I n d V R V F X A 1-1 TECHNICAL SPECIFICATIONS...
  • Page 4: Electrical Specifications

    • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Specifications 1-2 ELECTRICAL SPECIFICATIONS FXAQ20MAVE FXAQ25MAVE FXAQ32MAVE FXAQ40MAVE FXAQ50MAVE FXAQ63MAVE Power Supply Name Phase Frequency Voltage 220-240 Current Minimum circuit amps 0.30 0.40 0.40 0.40 0.40 0.60 (MCA) Maximum fuse amps (MFA) A 15.00...
  • Page 5: Safety Device Settings

    • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Safety device settings FXAQ20MA FXAQ25MA FXAQ32MA FXAQ40MA FXAQ50MA FXAQ63MA PC BOARD FUSE 250V 3A 4D034906F Options FXAQ20MA FXAQ25MA FXAQ32MA FXAQ40MA FXAQ50MA FXAQ63MA DRAIN PUMP KIT K-KDU572CVE ED39-226B ® • VRV Systems • Indoor Units...
  • Page 6: Control Systems

    • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Control systems Individual control systems FXAQ20MA FXAQ25MA FXAQ32MA FXAQ40MA FXAQ50MA FXAQ63MA WIRED REMOTE CONTROL BRC1D52 INFRARED REMOTE CONTROL Heat pump BRC7E618 Cooling only BRC7E619 Centralised control systems FXAQ20MA FXAQ25MA FXAQ32MA FXAQ40MA...
  • Page 7: Capacity Tables

    • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Capacity tables 5 - 1 Cooling capacity tables FXAQ-MA TC: Total capacity;kW – SHC: Sensible capacity;kW Indoor air temperature Outdoor Nominal 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB Unit size air temp.
  • Page 8 • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Capacity tables 5 - 1 Cooling capacity tables FXAQ-MA TC: Total capacity;kW – SHC: Sensible capacity;kW Indoor air temperature Outdoor Nominal 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB Unit size air temp.
  • Page 9: Heating Capacity Tables

    • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Capacity tables 5 - 2 Heating capacity tables FXAQ-MA Indoor air temperature °CDB Outdoor Unit Size Nominal capacity 16.0 18.0 20.0 21.0 22.0 24.0 air temperature °CDB °CWB -19.8 -20.0 -18.8 -19.0...
  • Page 10 • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Capacity tables 5 - 2 Heating capacity tables FXAQ-MA Indoor air temperature °CDB Outdoor Unit Size Nominal capacity 16.0 18.0 20.0 21.0 22.0 24.0 air temperature °CDB °CWB -19.8 -20.0 -18.8 -19.0...
  • Page 11: Dimensional Drawing & Centre Of Gravity

    • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FXAQ20,25,32MA Piping direction Approx. 400 Part name Description Dimensions for Front panel full open front panel Front grill Air outlet Gas pipe ø...
  • Page 12 • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FXAQ63MA Piping direction Approx. 400 Part name Description Front panel Front grill Air outlet Dimensions for full open front Gas pipe ø...
  • Page 13: Piping Diagram

    • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Piping diagram FXAQ-MA Heat exchanger Liquid pipe connection port Filter Filter Electronic Gas pipe connection port expansion valve Refrigerant flow Cooling Heating Piping connection diameters Model Liquid FXAQ20,25,32,40,50MA ø12.7 ø6.4 FXAQ63MA ø15.9...
  • Page 14: Wiring Diagram

    • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Wiring diagram 8 - 1 Wiring diagram FXAQ-MA Power supply 220-240V 220V 50Hz 60Hz Note 5 Receiver/display unit (Infrared remote control) Note 2 Note 5 Input from outside Transmission wiring Central remote control...
  • Page 15: Sound Data

    • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Sound data 9 - 1 Sound pressure spectrum FXAQ20MA 4D037087D FXAQ25MA 4D037088D Approximate Approximate treshold hearing for treshold hearing for continuous noise continuous noise Ocatve band center frequency (Hz) Ocatve band center frequency (Hz)
  • Page 16 • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Sound data 9 - 1 Sound pressure spectrum FXAQ50MA 4D038514A FXAQ63MA 4D038515A Approximate Approximate treshold hearing for treshold hearing for continuous noise continuous noise Ocatve band center frequency (Hz) Ocatve band center frequency (Hz)
  • Page 17: Installation

    • Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE Installation 10 - 1 Service space 1 Select an installation site where the following conditions are fulfilled and that meets with your customer’s approval. • In the upper space (including the back of the ceiling) of the indoor unit where there is no possible dripping of water from the refrigerant pipe, drain pipe, water pipe, etc.
  • Page 18 The present publication is drawn up by way of information only and conditioning equipment, compressors and Quality Management System in accordance with the does not constitute an offer binding upon Daikin Europe N.V.. Daikin refrigerants has led to its close involvement in ISO9001 standard. ISO9001 pertains to quality Europe N.V.