7.2

Monitoring alarms

34 (60)
In this menu the name of the supervised unit, installation date and installer are
changeable. To change these parameters select Modify: Q1 menu option 4,7,2,1
for name, 4,7,4,1,1 for date and 4,7,4,1,2 for installer. Note that the maximum
lengths are 15 characters for date and name and 20 characters for installer. There
are two dates for installation date, First and Last. In very first time the First and
Last gets the same date (Q1: 4,7,4,1,1), and after that only the Last gets new value
(Q1: 4,7,4,1,1).
The Fault display (see the figure below) gives error information concerning the
unit chosen. The information includes the name, which the user has given to the
supervised device, supervision block, for example line or port, the type of a fault,
and the fault status shown by the alarm class (A = urgent, B = non-urgent, AS =
urgent, service alarm).
*DNT2Mi (AS)
Line:
-no incoming signal
Figure 18.
Example of Fault display
In the example above, the first line consists of the name given to the supervised
device and alarm class (AS), the second line shows the supervision block, and the
third line the type of the fault.
Table below shows alarm information from Port and Line interfaces and alarms
from the equipment itself.
DNT2Mi-fp
SB 0, MODEM
Code
Severity
0x7c
AS
0x80
AS
0x91
A,B
© Nokia Corporation
Nokia Proprietary and Confidential
DNT2Mi-fp Data Network Terminal User manual
Q1 message
Sync. fault in clock recovery
Fault equipment
Temperature error
DN0445814