11. STANDALONE TEST

11.1 Setting Method

11.1.1 COM Port

In the "Dialog Menu", select the values as explained below.
• Port : select a correct COM port
• Baudrate : 115200
• Leave the rest as default values

11.1.2 Tx Test

1. Selecting Channel
• Select one of EGSM, DCS Band and input appropriate channel.
2. Selecting APC
a. Select either Power level or DAC value.
b. Power level
• Input appropriate value EGSM (between 5~19) or DCS (between 0~15)
c. DAC value
• You may adjust directly the power level with DAC values.

11.1.3 Rx Test

1. Selecting Channel
• Select one of EGSM , DCS Band and input appropriate channel.
2. Automatic Gain Control and Instrument Power level
See if the value of RSSI is close to -60dBm when setting the value 40 AGC Value Setting.
• Normal phone should indicate the value of RSSI close to -60dBm.
11. STANDALONE TEST