Standalone Test; Setting Method - LG MG220 Service Manual

Hide thumbs Also See for MG220:
Table of Contents

Advertisement

10. STANDALONE TEST

10. STANDALONE TEST

10.1 Setting Method

10.1.1 COM Port
In the "Dialog Menu", select the values as explained below.
• Port : select a correct COM port
• Baudrate : 115200
• Leave the rest as default values
10.1.2 Tx Test
1. Selecting Channel
• Select one of GSM850, EGSM, DCS, PCS Band and input appropriate channel.
2. Selecting VRAMP
a. Select either Power level or DAC value.
b. Power level
• Input appropriate value GSM (between 5~19) or PCS (between 0~15)
c. DAC value
• You may adjust directly the power level with DAC values.
10.1.3 Rx Test
1. Selecting Channel
• Select one of GSM850, PCS Band and input appropriate channel.
2. Automatic Gain Control and Instrument Power level
See if the value of RSSI is close to -60dBm when setting the value 40 AGC Value Setting.
• Normal phone should indicate the value of RSSI close to -60dBm.
- 110 -

Advertisement

Table of Contents
loading

Table of Contents