Installation Instructions Natural Gas To Lp Gas - Haier HLTD500AGW Service Manual

Top load electric dryer
Hide thumbs Also See for HLTD500AGW:
Table of Contents

Advertisement

SERVICE MANUL
Model No.HLTD500AGW
7-8. Installation Instructions
Natural Gas to LP Gas Conversion Kit No.
Dryer Models GDG750AW & RDG350AW & Other Natural Gas Dryers
THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORITY
HAVING JURISDICTION. THE INFORMATION IN THESE INSTRUCTIONS MUST BE FOLLOWED TO MINIMIZE
THE RISK OF FIRE OR EXPLOSION OR TO PREVENT PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
THE QUALIFIED SERVICE AGENCY IS RESPONSIBLE FOR THE PROPER INSTALLATION OF THIS KIT. THE
INSTALLATION IS NOT PROPER AND COMPLETE UNTIL THE OPERATION OF THE CONVERTED APPLIANCE IS
CHECKED AS SPECIFIED IN THE MANUFACTURER'S INSTRUCTIONS SUPPLIED WITH THIS KIT
THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE
PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE
REQUIREMENTS OF THE CSA B149.1, INSTALLATION CODE.
Important Note:
Installation of this kit converts the dryer from use with Natural Gas to use with LP Gas for
altitudes up to 4,500 feet above sea level. For installations at an altitude greater than 4,500 feet above sea
level, contact a qualified service agency for derating instructions.
Parts List
1 0030101224 Regulator Blocking Plug and
Main Burner Orifice No. 55
1 00305027 06 LP Gas Conversion Plate Sticker
1 00305027 05 LP Gas Conversion Service Sticker (English)
1 00305027 05A LP Gas Conversion Service Sticker (French)
1 00305027 04 LP Gas Valve Sticker (English)
1 00305027 04A LP Gas Valve Sticker (French)
1 00305027 15B Instructions
Gas input - 20,000 BTU/HR
Before converting the dryer to LP Gas, verify
that the incoming gas supply line is equipped
with a pressure regulator (located ahead of the
dryer) that will maintain the gas supply to the
dryer at
12.5 ± 1.5'' W .C. (31.8 ± 3.8cm W.C.)
Use a U '' tube manometer (or similar pressure
''
gauge) to check the pressure.
Installation Instructions
1. Disconnect the electrical power
to the dryer.
2. Shut off the gas supply to the dryer.
3. Remove the louvered vent panel
on the rear of the dryer. Disengage the
drum belt by rotating the idler pulley
down and away from the motor. Slide
the belt off of the pulleys. (Figure 1)
WARNING
- 22 -
003080
79 9
8

.
Regulator Blocking Plug
Main Burner Orifice
Motor Pulley
Drum Belt
Idler Pulley
Figure 1
Issue
Rev.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents