Monogram ZET1FHSS Installation Instructions Manual page 2

30” french door built-in wall ovens
Table of Contents

Advertisement

Available languages

Available languages

2 A
CUTOUT FOR SINGLE OVENS IN WALL CABINET
NOTE: If the cabinet does not have a front frame and the sides are less than ¾" (1.9 cm) thick, shim
both sides equally to establish the cutout width.
These ovens
are not
approved for
stackable
installations.
Opening
J
Between Inside
Walls Must be
at Least 28
"
1
2
(72.4 cm) Wide
E
Side-by-Side Installations
Install two ovens in separate cutouts.
Center Line
Center Line
30" Models
58
" (148.6 cm) if both ovens are French Door
1
2
42
1
" (108 cm) if only one oven is French Door
2
Cutout –
Cutout –
observe all
observe all
dimensions and
dimensions and
requirements.
requirements.
30" (76.2 cm) Min. if both ovens are French Door
14" (35.6 cm) Min. if only one oven is French Door
Dimension
Dimension Description
A
Cabinet width
B
Cutout width
C
Cutout height
D
Overlap of oven over side edges of cutout
E
Door swing depth - Allow additional clearances for
installation and oven usage
F
Overlap of oven top of cutout
G
Overlap of oven bottom of cutout
H
Junction box location
J
Door swing width - Allow additional clearances for
installation and oven usage
K
Countertop or cabinet door protrusion (measure if exist)
L
Gap between edge of countertop or cabinet door
to cabinet opening
B
H
Junction
Box
Location
(junction
box may
be located
in adjacent
cabinet)
F
D
G
22" (55.9
cm) Min. to
J
Bottom of
Junction
Box
Cutout Depth
23
1
"
2
(59.7 cm) Min.
Recommended
Cutout Location from
Floor
32
16
A
L
K
E
E
30" Single Oven
30" (76.2 cm)
28
" (72.4 cm) min.
1
2
28
" (72.7 cm) max.
5
8
27
" (69.2 cm) min.
1
4
27
5
" (69.4 cm) max.
16
11
" (1.75 cm)
16
16
1
" (41.3 cm) min.
4
1" (2.5 cm) min.
1
" (3.2 cm)
1
4
9
" (24.1 cm) max.
1
2
right side only
14" (35.6 cm) min.
Measure "K"
If K = 0, L = 0, Otherwise
L = K + 1" (2.54 cm) min.
2 B
CUTOUT FOR INSTALLATION OVER A WARMING DRAWER
NOTE: Install the oven only with specific models listed on the label located on top of the oven.
NOTE: Additional clearances between cutouts may be required. Check to be sure the oven supports
above the Warming Drawer location do not obstruct the required interior depth and height.
When installing a Warming Drawer below a single or double oven, a separate 120V, 60 HZ, properly
grounded receptacle must be installed. Refer to installation instructions packed with
the Warming Drawer for specific installation requirements.
C
Anti-Tip Block Against
Rear Wall Per Warming
Drawer Requirement
" (82.6 cm)
1
2
1
" (41.3 cm) Min.
4
C
2" (5.1 cm)
Min.
Per Warming
Drawer
Requirement

Advertisement

Table of Contents
loading