Gas Plumbing Requirements - Lynx l27 Installation, Care & Use Manual

Table of Contents

Advertisement

Gas Plumbing
Requirements
B
• A pressure
regulator
must be installed
on all gas equipment.
All local codes require
that
a pressure
regulator
be installed.
Removing
or failing
to install the pressure
regulator
can
result in fire and serious
bodily
harm.
• An installer
supplied
gas shut-off
valve must be installed
in an easily accessible
location
for
all hard-plumbed
natural
gas and liquid
propane
applications.
• In order for a Lynx Grill to perform
properly
you must have adequate
gas plumbing.
Please
see the guidelines
below
to help ensure that you have the appropriate
gas plumbing
with
respect
to gas pipe diameter,
length
of pipe run and the grills BTU requirements.
Diameter
10 ft.
20 ft.
30 ft.
40 ft.
50 ft.
60 ft.
70 ft.
80 ft.
1/2"
170,000
BTU
118,000
BTU
95,000
BTU
80,000
BTU
71,000
BTU
64,000
BTU
60,000
BTU
55,000
BTU
3/4"
360,000
BTU
245,000
BTU
198,000
BTU
169,000
BTU
150,000
BTU
135,000
BTU
123,000
BTU
115,000
BTU
Grill Model
Main Burners
Rotisserie Burners
Total
L27
50,000 BTU
15,000 BTU
65,000 BTU
L30
50,000 BTU
15,000 BTU
65,000 BTU
L36
75,000 BTU
15,000 BTU
90,000 BTU
L42
75,000 BTU
16,000 BTU
91,000 BTU
L54
100,000
BTU
30,000 BTU
130,000
BTU
Natural Gas Supply pressure = 7"water column (17.8 cm) min. and
pressure under full load = 4"water column (10.2 cm) minimum.
Liquid Propane Supply Pressure = 11-14"water column (27.9 - 35.5 cm), not to exceed 14"water column and
pressure = 11"water column (27.0 cm) minimum.
Note: All BTU and water column requirements are approximations.
28 B_lyNX