Download Print this page

Mitsubishi Electric VL-100U-E Manual page 5

Home use losnay type

Advertisement

Cleaning the Lossnay Core
Lossnay Core
Cleaning the panel/main unit
• If the panel or main unit becomes dirty, wipe it with a well-wrung cloth soaked in a solution of neutral detergent and
lukewarm water, then with a clean cloth to remove any traces of detergent.
Note
• Use of the following substances may cause deterioration or discoloration: Paint thinner, alcohol, benzene, gasoline,
kerosene, sprays, alkaline detergents, or chemical cleansers.
Re-assembly and checking after maintenance
Lossnay Core
1
Air filter
Rib
2
Do not use water
Catch
Square hole
Main unit
Use a vacuum cleaner to remove surface dirt
and dust.
• Apply the vacuum cleaner's nozzle lightly to the
surface.
Note
• Do not let water, chemicals or volatile solutions
come into contact with the Lossnay Core.
• Do not place the Lossnay Core close to a flame.
• Do not press wires, screwdrivers or vacuum
cleaners with hard nozzles into the surface.
CAUTION
• After maintenance, re-attach parts secure-
ly.
(Falling parts may cause injuries.)
Air filter/Lossnay Core
1. Attach the air filter to the Lossnay Core.
2. Push in the Lossnay Core with the air filter at the
bottom.
Panel attachment/checking
1. Hang the panel at the top of the main unit, and hold
the bottom while pressing it in.
2. Tighten the loosened screw to secure the panel in
place.
3. Insert the power plug into the wall outlet.
Note
• Be sure to insert the power plug after installing the
panel.
4. Check the following:
(1) Are the main unit and panel attached securely?
(2) Is the unit making a strange noise?
(3) Is air coming out of the unit normally?
(Be sure to check the unit while in operation.)
– 5 –

Advertisement

loading