For models ZIFI240 and ZIBI240 with Custom Door Panels and Handles

THE INSTALLATION SPACE

NOTE: If installing between
frameless cabinets, a 1/2"
wide filler strip or side panel
may be needed on the hinge
side. The filler strip will act as
a spacer between the door
case and adjacent cabinet
and will prevent interference
with the cabinet door swing.
The width of the opening
must include the filler panels.
The product must be installed so that the custom panel front will
project 2-3/4" forward of adjacent cabinets. This position will allow
a full door swing and prevent interference with adjacent cabinetry.
The opening between cabinets must be 23-3/4" minimum. These
models can not be installed flush in 24"-deep cabinets.
• All models may be used freestanding.
Additional Specifications
• A 120 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch circuit
or circuit breaker is recommended. Install a properly
grounded 3-prong electrical receptacle recessed into
the back wall as shown. Electrical must be located
on rear wall as shown. NOTE: GFCI (ground fault circuit
interrupter) is not recommended.
Black or Stainless Steel Toekick Options
• These products are shipped with a stainless steel toekick
and a black toekick. For shipping purposes, one of the
toekicks will be secured to the back of the unit, and the
second will be installed on the unit. Keep the unused
toekick and any unused parts for future use.
Standard
Installation
Front edge of
CABINET
product case
Front face
Dim. A
In a standard installation, the product
will project forward of adjacent
cabinets. See Dim. A.
Product
Dim. A
ZIFI240
ZIBI240
Design Guide
NOTE:
Water line location for
ZIBI240 model only
CABINET
110°
120°
2-3/4"
2-5/8"

SIDE-BY-SIDE INSTALLATIONS

For a complete refreshment center, install a Fresh-
Food Refrigerator beside a Double-Drawer Refrigerator,
Beverage Center or Wine Chiller/Wine Reserve. Or, install
a Refrigerator with Icemaker beside a Wine Chiller/Wine
Reserve.
• A side-by-side installation requires at least a 47-1/2"-
wide opening. No trim kits required.
• Products must operate from separate, properly
grounded receptacles.
34-1/2"-35"

PRODUCT CLEARANCES

The Fresh-Food Refrigerator or Bar Refrigerator with
Icemaker is factory set for a 110° door swing.
When installed in a corner:
• Allow 16" minimum clearance on the hinge side for a
full 110° door swing.
• Allow 4-1/2" min. clearance on the hinge side for the
90° door swing and to allow racks to slide out.
NOTE: Custom handle clearances may vary.
16" Minimum to Wall
110 Door
Swing
110
NOTE: Right hand models illustrated. Allow the same
clearances on the opposite side for left hand fresh food
models ZIFI240 and ZIFS240 only. Models ZIBI240 and
ZIBS240 are not available with left hand door swing.
• Test the door swing. Carefully open and close the door.
The door should not rub or catch on adjacent cabinetry.
NOTE: When installing custom panel and handle,
use above clearances as a general guide but adjust
according to the installation.
Choose the location:
• These products may be closed in on the top and
three sides as long as the front is unobstructed for air
circulation and proper access to the door.
• Do not install these products where the temperature
will go below 55°F (13°C) or above 90°F (32°C).
• These products are not designed to be stacked one
over the other.
7
Locate
Outlet
10-1/2"
10-1/2"
24"
14"
9"
9"
15"
1-1/2"
47-1/2" Min.
90 Door
21-5/8"
Swing
90
4-1/2" Minimum to Wall
23-5/8"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zifs240Zibi240Zibs240

Table of Contents