Worcester Greenstar Heatslave II ErP 12/18 Installation, Commissioning And Servicing Instruction Manual page 42

Floor standing oil-fired condensing combination boiler using conventional and room sealed flue
Table of Contents

Advertisement

Service and Spares
M
M
K
6
1
A
C
Fig. 79
Nominal boiler rating at normal operating temperature using Kerosene (Class C2)
Oil pump pressure
Nozzle
bar
psi
Greenstar Heatslave II 12/18 model
0.35 x 80° SR
9.0
132
0.45 x 60° ES
7.5
110
0.55 x 80° ES
7.8
115
Greenstar Heatslave II 18/25 model
0.50 x 80° ES
8.5
125
0.60 x 60° ES
8.5
125
0.75 x 80° ES
7.5
110
Greenstar Heatslave II 25/32 model
0.75 x 80° ES
7.5
110
0.75 x 80° ES
10.0
147
0.85 x 80° EH
9.5
140
Table 9 Combustion settings
42
7
N
O
4
H
G
3
F
2
L
D
B
6 720 805 209-59.1TL
Approximate
flue gas
Fuel flow rate
temperature
Kg/h
l/h
°C
1.04
1.32
72
1.28
1.63
77
1.54
1.96
80
1.58
1.96
76
1.84
2.33
81
2.15
2.72
87
2.15
2.72
79
2.46
3.12
81
2.78
3.52
86
Approximate
Input
air setting
(appliance)
%CO2
kW
11.0
3.0
12.4
11.5
5.0
15.4
12.0
5.0
18.5
11.5
3.0
18.5
12.0
3.5
22.1
12.0
4.5
25.7
11.5
3.5
25.7
12.0
4.5
29.4
12.5
5.0
33.0
Greenstar Heatslave II
Output
Air damper
(appliance)
disk setting
Burner head
kW
12.0
12/15
LD2X Short
15
12/15
LD2X Short
18.0
18
LD2X Short
18.0
18
LD2SX Short
21.5
21.5
LD2SX Short
25.0
25
LD2SX Short
25.0
N/A
T2 Short
28.5
N/A
T2 Short
32.0
N/A
T2 Short
ErP -
6 720 813 344 (2014/09)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents