Worcester Greenstar Heatslave II ErP 12/18 Installation, Commissioning And Servicing Instruction Manual page 35

Floor standing oil-fired condensing combination boiler using conventional and room sealed flue
Table of Contents

Advertisement

[6]
Centigrade symbol
Displays next to the temperature reading.
[7]
Confirmation symbol
This symbol confirms a manual change.
[8]
Alpha/Numerical display
Displays a temperature or boiler status code.
[9]
Text display
Displays ECO or diagnostic code.
Status code
During normal operation various status codes can be displayed by
pressing the service button.
The first screen of the information menu displays the current status
code, this will change as the boiler runs through the various modes and
sequences.
These are not faults, but provide information concerning the current
status.
Status
Code
200
CH active
The Central Heating system is being heated.
201
DHW active
The Domestic Hot Water is being heated/
tank is being heated.
202
CH Anti rapid-
Time delay to prevent rapid-cycling of the
cycle mode
boiler on the room thermostat.
203
System stand-by The boiler has no CH or DHW demands.
270
Power up mode The boiler is ON, warming up and running self
check routines. This lasts approximately
35 seconds.
358
Three way valve
Anti-seize operation. If the diverter valve has
anti-seize
not moved in 24 hours, the valve is operated
to prevent seizing, duration approximately
10 seconds.
Table 7
Selecting Service Menus
1. Press and hold
and
ok
display will show Menu 1.
Double up or down arrows
indicate that the menu can only be
scrolled up or down.
An up and down arrow
indicates position in the menu where options
can be scrolled either up or down.
1
Fig. 62
2. Scroll up and down through the menus with the arrow
buttons
Greenstar Heatslave II
ErP -
6 720 813 344 (2014/09)
buttons together for 1 second, the
6 720 805 209-40.1TL
2
Fig. 63
Menu 2 - Boiler parameters
3. Select Menu 2 via the
and
▶ Press and hold
OK button, for 1 second to enter Menu 2.
ok
The menu lists the boiler parameters, that can be adjusted in this menu.
3
Fig. 64
To modify setting
4. Select the desired menu option using the arrow buttons (refer to
figure 65) and press the OK button, the option will flash.
▶ Adjust the parameter using the up and down arrow buttons and press
the OK button to confirm.
A tick
will appear on the display for 3 seconds to confirm the
update of the new value.
The same process is used for adjusting Menus 1 & 2.
4
Fig. 65
Commissioning
6 720 805 209-41.1TL
arrow buttons.
6 720 805 209-42.1TL
6 720 805 209-43.1TL
35

Hide quick links:

Advertisement

Table of Contents
loading