5.3

Connecting the inputs

This diagram shows the
connection of external
alarm contacts
to the accessory module.
(for functions 3 and 5).
This diagram shows the
connection of external
alarm contacts
with 2.2 kΩ terminal resistors
to the accessory module
(for functions 3 and 5).
5.4

Connecting the outputs

There are three
different ways of
connecting the
outputs.
1. OP1/0 V
Output OP1 becomes
+12 V when activated.
2. OP2/12 V
Output OP2 becomes
0 V when activated.
3. OP4/C4
Use this connection type if the output is to be used as a relay
(NO).
Note the different jumper positions.
5.5

Connecting the siren

The cable of the external siren is connected to the accessory
module using the RJ12 plug. The cable is inserted into the RJ12
plug connector.

6. Programming

Program the WAM as follows: Firstly, connect the power supply to
the accessory module (either via battery or via the 12 V PSU).
1
12V
12V
0V
0V
RJ12