Sony F35 Operation Manual page 80

Digital cinematography camera
Hide thumbs Also See for F35:
Table of Contents

Advertisement

MAINTENANCE menu
Page title &
purpose
<OUTPUT
M07
FORMAT>
[M03]
Setting the output
video format
<DOWN
M08
CONVERTER>
[M04]
Setting the aspect
ratio for VBS output
<POWER SAVE>
M09
[M05]
Selecting the output
power save mode
<BATT ALARM
M10
SET>
[M06]
Setting the voltage
values to trigger
alarm indications
<GENLOCK>
M11
[M07]
Adjusting Genlock
with status
indications
<DATE>
M12
[M08]
Setting the built-in
clock
80
Menu List
No.
Item
CURRENT
SCAN
FRAME
SIGNAL
SELECT FPS
SET FORMAT
ASPECT
MONITOR OUT
DOWN CONVERTER
DC IN (24 V)
TYPE
NEAR END
END
DC IN (12 V)
TYPE
NEAR END
END
REFERENCE
STATUS
H PHASE
DATE/TIME
Default
Settings
23.98PsF 4:4:4
PROGRESSIVE PROGRESSIVE,
INTERLACE
23.98
23.98, 24, 25, 29.97, 30,
50, 59.94, 60
4:4:4 RGB
4:4:4 RGB, 4:2:2 YCbCr
OFF
ON, OFF
Execute by ENTER.
LB
SQ, LB, EC
ACTIVE
PWR SAVE, ACTIVE
ACTIVE
PWR SAVE, ACTIVE
AC ADP
BATT1, BATT2, AC ADP BATT1/BATT2: Batteries
22.2 V
0.1 to 30.0 V
21.6 V
0 to 29.9 V
AC ADP
BATT1, BATT2, AC ADP BATT1/BATT2: Batteries
11.1 V
11.0 to 17.0 V
10.8 V
10.5 to 14.0 V
INTERNAL, GENLOCK
IN
OK, NG, NO SIGNAL
0
–511 to 511
yyyy/mm/dd
hh : mm
Remarks
The current format is
displayed.
When INTERLACE is
selected for SCAN, select
half the value of the field
frequency in FRAME.
SQ: Squeeze
LB: Letter Box
EC: Edge Crop
AC ADP: AC adaptor
Fixed to the default value
for AC ADP
Fixed to the default value
for AC ADP
AC ADP: AC adaptor
Fixed to the default value
for AC ADP
Fixed to the default value
for AC ADP
display only
display only
To adjust the H phase for
genlock (With a CA-F101
mounted, "– – –" is
displayed and the setting
cannot be changed.)

Hide quick links: