Safety-Check Out; Factory-Shipped Condition - Onkyo DV-SP1000 Service Manual

Hide thumbs Also See for DV-SP1000:
Table of Contents

Advertisement

QQ
3 7 63 1515 0
SERVICE PROCEDURES-2

2. Safety-check out

(Only U.S.A. model)
After correcting the original service problem perform the
following safety check before releasing the set to the customer
Connect the insulating-resistance tester between the plug of
power supply cord and terminal GND on the back panel.
Specifications: More than 10M ohm at 500V
INITIALIZING

Factory-shipped condition

Push button "ON" (Mechanical SW) Except <DC1N>
Press the [STOP] and [STANDBY] same time.
(Wait until FL display "No Disc") .
Push button "STANDBY".
Others
SURR. MODE Switch -------- "1" position
Mechanical power switch ---- ON
TE