12 Measurements and Adjustments
This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in
Troubleshooting Guide (P.32)
12.1. Equipment Required
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
Hewlett Packard, 53131A is recommended.
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
This equipment may be useful in order to precisely adjust like a mass production.
12.2. The Setting Method of JIG
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: PNZZTG6841M
12.2.1. Connections (Base Unit)
Connect the AC adaptor.
Connect the JIG Cable GND (black).
Connect the JIG Cable RX (red) and TX (yellow).
AC adaptor
DC JACK
1
Base unit P. C. board
Note:
*: COM port names may vary depending on what your PC calls it.
KX-TG6841B/KX-TG6842B/KX-TG6843B/KX-TG6844B/KX-TG6845B/KX-TG6873B/KX-TGA680B
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E),
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
Resistor
R2
R3
R4
R7
JIG Cable
3
3
UTX
URX
GND
2
GND (black)
53
change
the
following
Old value (kΩ)
New value (kΩ)
22
3.3
22
3.3
22
4.7
4.7
10
UTX (yellow)
To Serial Port
URX (red)
(COM port 1*)
values
of
PC