5
Dimensional drawings
5 - 1 Dimensional Drawings
FXFQ125P9
Piping side
Drain side
View A
Hanging bolt
NOTE
1
Location of the nameplates - Unit body: on the control box - Decoration panel: on the panel frame at the motor side under the corner cover
2
When installing an optional accessory, refer to the installation drawings
For the fresh air intake kit an inspection port is necessary
3
In case of using a wireles remote control, this position will be a signal receiver. Refer to the drawing of the wireless remote control for more detail.
4
Make sure the spacing between the ceiling and the cassette is no more than 35mm. Max cailing opening: 910mm.
5
When the conditions exceed 30°C and RH 80% in the ceiling or fresh air is inducted into the ceiling, an additionalinsulation is required (polyethylene foam,
thickness 10mm or more).
FXFQ125P9VEB
Piping side
Drain side
VIEW A
Hanging bolt
NOTES
1.
Location of the nameplates:
•
Unit body: on the control box.
•
Decoration panel: on the panel frame at the motor side under the
corner cover
2.
When installing an optional accessory, refer to the installation drawings.
•
For the fresh air intake kit an inspection part is necessary
3.
Make sure the spacing between the ceiling and the cassette is no more
than 35mm. Max. ceiling opening: 910mm
4.
When the conditions exceed 30°C and RH 80% in de ceiling or fresh
air is included into the ceiling, an additional insulation is required
(polyethylene foam, thickness 10mm or more).
• Indoor Unit • Round flow cassette • FXFQ-P9
(Ceiling opening)
300 or less
(Suspension position)
see note 3
see note 4
860~910 (Ceiling opening)
710 (Suspension position)
300 or less
See note 3
5.
Installation direction
Piping
®
• VRV
Systems • Indoor Unit
see note 4
Please respect the distances as shown on figure below
see note 4
See note 3
6.
Please respect the distances as shown on fi gure below
(*1) Does not count for build in light
(*2) Space needed to enter with vacuum-cleaner tube.
(*3) Keep the exhaust of decoration panel free.
See note 3
200mm or
more (*4)
1500mm or
more (*4)
Dust
opening
Piping
(*4) In case a discharge opening is closed with the 'sealing member' option,
Suction
grill
Item
Name
Remark
1
Liquid pipe connection
ø9.52 (Flare connection)
2
Gas pipe connection
ø15.90 (Flare connection)
3
Drain pipe connection
VP25 (ODø32, IDø25)
4
Power supply entry hole
5
Transmission wiring entry hole
6
Air discharge opening
7
Air suction grille
8
Corner decoration cover
9
Drain hose
ODø32, IDø25
10
Knock out hole
View B
External
Other unit
Ventilator
surface
light
1500 or more
2000 or more
4000 or more
1500 mm
or more (*)
200 mm
or more
1500 mm
1500 mm
or more (*)
or more (*)
200 mm
1500 mm
or more
or more (*)
(*) In case a discharge opening is closed with
the "sealing member" option, the distance of
1500 mm can be reduced to 500 mm on the
closed side.
3TW28914-1C
Nr
Name
Description
1
Liquid pipe connection
Ø9.52 fl are connection
2
Gas pipe connection
Ø15.90 fl are connection
3
Drain pipe connection
VP25 (O.D.Ø32, I.D. Ø25)
4
Power supply entry hole
5
Transmission wiring entry hole
6
Air discharge opening
7
Air suction grille
8
Corner decoration cover
9
Drain hose
O.D.Ø32, I.D. Ø26
10 Knock out hole
VIEW B
Ventilator
Other unit
External
surface
light (*1)
256
1500 or more
2000 or more
4000 or more
1500mm or
more (*4)
1500mm or
more (*4)
200mm or
more (*4)
1500mm or
more (*4)
the distance of 1500mm can be reduced to 500 mm on the closed side.
3TW32544-1
13