Read and Save These Instructions
All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS

K-SERIES UNDER CABINET HOOD
Read All Instructions Thoroughly Before Beginning Installation
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction. Switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally during installation.
B. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
C. Ducted fans must always be vented to the outdoors.
D. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and local code authorities.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL
L114A 1109A
DUCTWORK
Page 1
U L
C
US
R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the K250 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vent-a-Hood K250

  • Page 1: Read And Save These Instructions

    Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A.
  • Page 2 20 feet, increase the duct diameter by one inch for every ten feet of duct. A 90 degree elbow is equal to 5 feet of duct. Using Vent-A-Hood roof jacks or wall louvers (back page) will ensure proper efficiency. Airflow must not be restricted at the end of the duct run. Do not use screen wire or spring-loaded doors on wall louvers or roof jacks.
  • Page 3 1”. This will allow the transition to engage 1” inside of the duct. Consult the connection diagram (below) for further details on exhaust outlet placement. Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is provided on the back page of this instruction sheet.
  • Page 4 Amps Sones SP@0.0" SP@0.1" SP@0.2" SP@0.3" Duct Size K250 (Top Vent) 1550 7" (38 in. K250 (Back Vent) 1550 7" (38 in. • Because the Magic Lung blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more ®...
  • Page 5 VENTING ACCESSORIES WALL LOUVER RECTANGULAR WALL LOUVER LOW PROFILE ROOF JACK ADJUSTABLE ELBOW (MAXIMUM 4/12 PITCH) 8 �⁄�” 8 ½” 6” 10” 7” Back VP513 - 8 ½” 6” 8” VP514 - 9 �⁄��” View 3 ¼” 7” 6” 16 ¾” VP515 - 10 �⁄�”...

This manual is also suitable for:

K series

Table of Contents