Vent-a-Hood B100 Single Installation Instructions Manual

Vent-a-hood wall mount hood installation instructions

Advertisement

Read and Save These Instructions

All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS

Read All Instructions Thoroughly Before Beginning Installation
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s)
in accordance with all applicable codes and standards, including fire-
rated construction. Switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally
during installation.
B. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
C. Ducted fans must always be vented to the outdoors.
D. Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and local code authorities.
E. ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to
a maximum of 15 CFM per 100 square feet of occupiable space, unless a
back drafting test is performed or make-up air is provided. Consult a local
HVAC engineer for make-up air evaluation.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL
L110 1213A
WALL MOUNT HOOD
DUCTWORK
Page 1
U L
C
US
R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B100 Single and is the answer not in the manual?

Questions and answers

mike
May 16, 2025

how to remove B100MSL

1 comments:
Mr. Anderson
May 22, 2025

To remove the Vent-a-Hood B100 Single blower unit:

1. Make sure the power is turned off and locked at the service panel.
2. Remove the hood from its packaging and place the back on the floor or countertop.
3. Loosen the two brass screws on the bottom of the blower shield (A) and remove the shield.
4. Gently close the back draft damper from the top side of the hood.
5. Unsnap the suitcase latches (B) on each side of the blower housing.
6. Pull the housing forward and tip it to clear the blower wheel, then remove it from the hood.
7. Remove the three screws securing the blower motor.
8. Unplug and remove the motor, being careful not to damage the blower wheel.

It is not necessary to remove the blower wheel from the motor.

This answer is automatically generated

mike
May 16, 2025

how do i remove B100MSL

1 comments:
Mr. Anderson
May 22, 2025

To remove the Vent-a-Hood B100 Single:

1. Follow label instructions.
2. Remove the motor plate.
3. Unplug the motor.
4. Carefully remove the motor without damaging the blower wheel.

Reinstallation steps include:
1. Connect electrical wires: black to black, white to white, and ground to the provided lug.
2. Replace the motor and plug it back in.
3. Replace the blower front, ensure it is secured, and confirm the blower wheel turns freely.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Vent-a-Hood B100 Single

  • Page 1: Read And Save These Instructions

    Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A.
  • Page 2 Ducting Do’s and Don’ts General Requirements • Observe local codes regarding special duct requirements and placement of duct against combustibles. • Using Vent-A-Hood transitions (back page) will ensure proper efficiency. • Using Vent-A-Hood roof jacks or wall louvers (back page) will ensure proper efficiency. • Where possible, seal joints with duct tape. • The hood must be ducted to the outdoors without restrictions.
  • Page 3 Method 2: Install the duct(s) from the outside of the home to the ceiling over the exhaust outlet(s) on the hood. The end of the duct(s) should extend 1" below the ceiling. Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is provided on the back page of this instruction sheet.
  • Page 4 8” Outlet Electrical (2) of Hood of Hood 900 CFM B200 Dual & B100 Single Blower 1200 CFM Double B200 Dual Blowers (Top View) (Top View) 5) Remove the hood from its packaging and place the back of the hood on the floor or countertop in front of the wall where it will hang.
  • Page 5 SP@0.1" SP@0.2" SP@0.3" Duct Size B100 Single 1550 6" (28 in. B200 Dual 1550 8" (50 in. B200 Dual & B100 Single 1550 1350 VP562: 10" (79 in. Two B200 Duals 1550 1200 1800 1062 VP563: 12" (113 in. * Add 2.5 amps for each warming light and 0.5 amp for each halogen light.
  • Page 6 Installation Details Continued 14) FOR BACK VENTING APPLICATIONS ONLY. IF YOU ARE NOT BACK VENTING, PROCEED DIRECTLY TO STEP 15. Method 1: Place the appropriate elbow(s) on the top of the hood. Elbow(s) should be placed with the non-crimped end(s) on the inside the collar(s) of the exhaust outlet(s). Use duct tape to seal joints. Lift the hood up to the wall and hang the hood on the mounting strip, taking care to properly align the duct connection(s) between the elbow(s) and the duct(s) in the wall.
  • Page 7 VENTING ACCESSORIES WALL LOUVER WALL LOUVER WALL LOUVER RECTANGULAR WALL LOUVER 8 ⁄ ” 13” 11” 8 ½” 10” Back Back Back 6” 11” View View View 3 ¼” 7” 13” 6” 8” 1 ½” Flange 1 ½” Flange 1 ½” Flange MODEL MODEL MODEL...