Read and Save These Instructions
All Hoods Must Be Installed By A Qualified Installer
INSTALLATION INSTRUCTIONS
Read All Instructions Thoroughly Before Beginning Installation
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s)
in accordance with all applicable codes and standards, including fire-
rated construction. Switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally
during installation.
B. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
C. Ducted fans must always be vented to the outdoors.
D. Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and local code authorities.
E. ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to
a maximum of 15 CFM per 100 square feet of occupiable space, unless a
back drafting test is performed or make-up air is provided. Consult a local
HVAC engineer for make-up air evaluation.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL
L110 1213A
WALL MOUNT HOOD
DUCTWORK
Page 1
U L
C
US
R
Need help?
Do you have a question about the B100 Single and is the answer not in the manual?
Questions and answers
how to remove B100MSL
To remove the Vent-a-Hood B100 Single blower unit:
1. Make sure the power is turned off and locked at the service panel.
2. Remove the hood from its packaging and place the back on the floor or countertop.
3. Loosen the two brass screws on the bottom of the blower shield (A) and remove the shield.
4. Gently close the back draft damper from the top side of the hood.
5. Unsnap the suitcase latches (B) on each side of the blower housing.
6. Pull the housing forward and tip it to clear the blower wheel, then remove it from the hood.
7. Remove the three screws securing the blower motor.
8. Unplug and remove the motor, being careful not to damage the blower wheel.
It is not necessary to remove the blower wheel from the motor.
This answer is automatically generated
how do i remove B100MSL
To remove the Vent-a-Hood B100 Single:
1. Follow label instructions.
2. Remove the motor plate.
3. Unplug the motor.
4. Carefully remove the motor without damaging the blower wheel.
Reinstallation steps include:
1. Connect electrical wires: black to black, white to white, and ground to the provided lug.
2. Replace the motor and plug it back in.
3. Replace the blower front, ensure it is secured, and confirm the blower wheel turns freely.
This answer is automatically generated