[Description on Self-diagnosis Display]
Display Code
Countermeasure
Change the disk and turn off the main
C:32:01
power then back on.
Replace the floppy disk.
C:13:01
Format the floppy disk with the MVC-
FD71.
Checking of flash unit or replacement of
E:91:01
flash unit
E:61:00
Checking of lens drive circuit
E61:10

[Power supplying Method]

Use the AC power adaptor (BC-V615) when supplying the power to this set.
Note : The "Self-diagnosis" data is backed up by the coin lithiumbattery.
The data will be lost and initialized when the coin lithium battery
is removed.
Cause
Defective floppy disk.
• The type of floppy disk that cannot be
used by this machine, is inserted.
(Such as 2DD)
• Data is damaged.
• Unformatted disk is inserted.
Abnormality when flash is being
charged.
When failed in the focus initialization.