Description On Self-Diagnosis Display - Sony MVC-CD500 Service Manual

Digital still camera
Hide thumbs Also See for MVC-CD500:
Table of Contents

Advertisement

1-4. DESCRIPTION ON SELF-DIAGNOSIS DISPLAY

Display Code
Countermeasure
Change the disk and turn off the main
C:32:01
power then back on.
C:13:01
Replace the CD-R/RW disk.
Checking of flash unit or replacement of
E:91:01
flash unit
*1
E:61:00
Checking of lens drive circuit
*1
E:61:10
Note: The error code is cleared if the battery is removed.
*1 : The error display is given in two ways.
Self-diagnosis display
• C: ss: ss
The contents which can be handled
by customer, are displayed.
• E: ss: ss
The contents which can be handled
by engineer, are displayed.
Cause
Defective base unit.
• The type of CD-R/RW disk that cannot
be used by this machine, is inserted.
• Data is damaged.
Abnormality when flash is being
charged.
When failed in the focus initialization.
1-3E
MVC-CD500
Caution Display During Error
DRIVE ERROR
DISK ERROR
Flash LED
Flash display
Flashing at 3.2 Hz

Advertisement

Table of Contents
loading

Table of Contents