Important Notices - LaserLiner LaserRange-Master X2 Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10
Continuous measurement / min/max values:
device on
1x
A signal sounds at 1 second interval during the measurement.
The LC display shows the max value, the min value and
!
the current value. The max value is required to determine
diagonals while the min value is used to determine verticals
and horizontals.
Switch signal tone on/off:
device on
1x

Important notices

– The laser points to the location that will be measured.
No objects may get into the laser's line of measurement.
– The device compensates the measurement for different room
temperatures. Therefore allow the device a brief adaptation period
when changing locations with large temperature differences.
– The device is only conditionally useable in outdoor areas and
cannot be used in strong sunlight.
– The measurement results of outdoor measurements may be
influenced or falsified by rain, fog and snow.
– Carpeting, upholstery or curtains will not reflect the laser optimally.
Measure to flat surfaces.
– Measurements made through glass (window panes) can falsify
measurement results.
– An energy-saving function switches the device off automatically.
– The batteries must be replaced when the battery symbol (a) starts
to flash.
14
GB
activate
2x
2 sec
tone on
2 sec
start
stop
tone off
2 sec