APPENDICES
Lamp Replacing Procedure:
1. Switch off the power to the projector by pressing the " " button.
2. Allow the projector to cool down for at least 60 minutes.
3. Disconnect the power cord.
4. Unscrew the two screws on the lamp door. ①
5. Open and pull up the lamp door. ②
6. Unscrew the three screws on the lamp housing. ③
7. Pull out the lamp module slowly and carefully. ④
To replace the lamp module, reverse the previous steps.
8. Turn on the projector and use "Lamp Reset" after the lamp module is replaced.
Lamp Reset: (i) Press "Menu" (ii) Select "OPTIONS" (iii) Select "Lamp Set-
tings" (iv) Select "Lamp Reset" (v) Select "Yes".
50 English
2
1
3
4