3

Capacity tables

FTXS20CVMB + RXH20CVMB
Cooling capacity
Indoor
EWB
EDB
20
(°C)
(°C)
TC
SHC
14.0
20
1.86
1.68
0.46
16.0
22
2.01
1.81
0.47
18.0
25
2.16
1.95
0.48
19.0
27
2.24
2.01
0.48
22.0
30
2.47
2.22
0.50
24.0
32
2.63
2.36
0.51
Heating capacity
Indoor
EDB
-10
(°C)
TC
PI
16.0
1.49
0.55
18.0
1.48
0.58
20.0
1.46
0.61
21.0
1.46
0.62
22.0
1.45
0.64
24.0
1.44
0.66
FTXS25CVMB + RXH25CVMB
Cooling capacity
Indoor
EWB
EDB
20
(°C)
(°C)
TC
SHC
14.0
20
2.10
1.78
0.52
16.0
22
2.26
1.92
0.53
18.0
25
2.43
2.06
0.54
19.0
27
2.52
2.14
0.55
22.0
30
2.78
2.36
0.56
24.0
32
2.96
2.51
0.57
Heating capacity
Indoor
EDB
-10
(°C)
TC
PI
16.0
1.63
0.61
18.0
1.62
0.64
20.0
1.61
0.67
21.0
1.60
0.68
22.0
1.59
0.70
24.0
1.58
0.73
SYMBOLS
AFR:
Air flow rate
BF:
Bypass factor
EWB:
Entering wet bulb temp.
EDB:
Entering dry bulb temp.
TC:
Total capacity
SHC:
Sensible heating capacity
PI:
Power input
• Pair Application, Inverter Controlled Unit • R-410A • RXH20-25-35CVMB
25
PI
TC
SHC
PI
TC
1.80
1.62
0.52
1.74
1.95
1.75
0.53
1.88
2.09
1.88
0.54
2.02
2.16
1.95
0.54
2.09
2.39
2.15
0.56
2.31
2.54
2.29
0.57
2.45
230V [50Hz]
Outdoor temperature (°CWB)
-5
0
TC
PI
TC
PI
1.85
0.60
2.20
0.65
1.83
0.63
2.19
0.68
1.82
0.66
2.17
0.70
1.81
0.67
2.17
0.72
1.81
0.68
2.16
0.73
1.79
0.71
2.15
0.76
25
PI
TC
SHC
PI
TC
2.03
1.72
0.58
1.96
2.19
1.86
0.59
2.11
2.35
2.00
0.61
2.27
2.43
2.06
0.61
2.35
2.69
2.28
0.63
2.60
2.86
2.43
0.64
2.76
230V [50Hz]
Outdoor temperature (°CWB)
-5
0
TC
PI
TC
PI
2.02
0.66
2.41
0.71
2.01
0.69
2.40
0.74
1.99
0.72
2.38
0.77
1.99
0.74
2.38
0.79
1.98
0.75
2.37
0.80
1.97
0.78
2.35
0.83
(m
3
/min)
(°CWB)
(°CDB)
(kW)
(kW)
(kW)
• Split - Sky Air • Outdoor Units
230V [50Hz]
Outdoor temperature (°C)
30
32
SHC
PI
TC
SHC
1.57
0.57
1.71
1.54
1.69
0.58
1.85
1.66
1.82
0.59
1.98
1.79
1.88
0.60
2.05
1.85
2.08
0.61
2.27
2.04
2.21
0.63
2.41
2.17
AFR
7.8
6
10
TC
PI
TC
PI
2.63
0.71
2.91
0.74
2.61
0.73
2.90
0.77
2.60
0.76
2.88
0.80
2.59
0.77
2.88
0.81
2.59
0.79
2.87
0.83
2.57
0.81
2.86
0.85
3D044305
230V [50Hz]
Outdoor temperature (°C)
30
32
SHC
PI
TC
SHC
1.66
0.65
1.92
1.63
1.79
0.66
2.08
1.76
1.93
0.67
2.23
1.89
1.99
0.67
2.31
1.96
2.20
0.69
2.55
2.17
2.34
0.71
2.71
2.30
AFR
7.8
6
10
TC
PI
TC
PI
2.88
0.77
3.19
0.82
2.86
0.80
3.18
0.85
2.85
0.84
3.16
0.88
2.84
0.85
3.15
0.89
2.84
0.87
3.15
0.91
2.82
0.90
3.13
0.94
3D044306
NOTES
1. Ratings shown are net capacities which include a deduction for indoor fan
motor heat
2.
Shows nominal cooling capacities and power input
3. TC, PI and SHC must be calculated by interpolation using the figures in the
above tables. (Figures out of the tables should not be used for calculation.)
4. SHC is based on each EWB and EDB
SHC* = SHC correction for other dry bulb
3
SHC* = 0.02 x AFR (m
Add SHC* to SHC.
5. Capacities are based on the following conditions:
Corresponding refrigerant piping length:
Level difference:
6. Air flow rate (AFR) and Bypass factor (BF) are taburated above.
AFR
BF
35
PI
TC
SHC
PI
TC
0.58
1.67
1.50
0.59
1.60
0.59
1.80
1.62
0.60
1.72
0.60
1.93
1.74
0.61
1.85
0.61
2.00
1.80
0.62
1.92
0.62
2.21
1.99
0.64
2.12
0.64
2.35
2.12
0.65
2.25
AFR
BF
35
PI
TC
SHC
PI
TC
0.66
1.87
1.59
0.67
1.80
0.67
2.02
1.72
0.68
1.94
0.68
2.17
1.85
0.69
2.08
0.68
2.25
1.91
0.70
2.16
0.70
2.49
2.11
0.72
2.38
0.72
2.64
2.24
0.73
2.53
/min) x (1-BF) x (DB-EDB)
1
7.7
3
0.23
40
SHC
PI
1.44
0.64
1.55
0.65
1.67
0.67
1.72
0.67
1.91
0.69
2.03
0.70
7.7
0.23
40
SHC
PI
1.52
0.72
1.65
0.74
1.77
0.75
1.83
0.76
2.02
0.78
2.15
0.79
5 m