technical data RXH-C Pair Application, Inverter Controlled Unit Split Sky Air...
Page 2
Daikin Europe N.V. is participating Daikin Europe N.V. is approved by LRQA for its Quality in the EUROVENT Certification Programme. Management System in accordance with the ISO9001 Products are as listed in the EUROVENT standard.
Outdoor units for pair application + Daikin outdoor units can be mounted easily on a roof or terrace or simply placed against an outside wall. They are fitted with a swing compressor, renowned for its low noise and high energy efficiency.
• Pair Application, Inverter Controlled Unit • R-410A • RXH20-25-35CVMB Specifications TECHNICAL SPECIFICATIONS OUTDOOR UNITS RXH20CVMB RXH25CVMB RXH35CVMB DIMENSIONS Unit WEIGHT COLOUR Unit Ivory white SOUND LEVEL Sound pressure (1) (Cooling) high/low dB(A) 46/* 46/* 48/* Sound pressure (1) (Heating)
Page 6
: Full Load Amps 5. For more details concerning conditional connections, see : Rated motor output (W) http://www.daikineurope.com/extranet, select ’’Daikin Documentation’’ and select ’’conditional connection’’, ’’the requested product type’’ and ’’English’’ from the drop down lists, click the search button.
• Pair Application, Inverter Controlled Unit • R-410A • RXH20-25-35CVMB Dimensional drawings unit (mm) RXH20,25,35C Wall height on air outlet side = Minimum space for air passage 4 x holes for anchor bolts (M8 or M10) less than 1200 Drain outlet (I.D.
• Pair Application, Inverter Controlled Unit • R-410A • RXH20-25-35CVMB Operation range RXH20,25,35C Cooling Heating (−10°CDB) Indoor temp. (°CWB) Indoor temp. (°CDB) Notes: The graph is based on the following conditions: 1. Equivalent piping length 7.5 m 2. Level difference 4D044281 3.
• Pair Application, Inverter Controlled Unit • R-410A • RXH20-25-35CVMB Piping diagrams RXH20,25C Outdoor unit Heat exchanger Outdoor temperature thermistor Heat exchanger thermistor Motor operated valve Muffler with filter Propeller fan Muffler with filter Field piping Liquid stop valve Muffler Field piping Compressor Accumulator...
• Pair Application, Inverter Controlled Unit • R-410A • RXH20-25-35CVMB Sound level Sound level data Cooling only / Heat pump: Sound pressure level Sound power level 230V, 50Hz Model Cooling/heating Measuring location (cooling/heating) RXH20C 46/47 61/62 RXH25C 46/47 61/62 RXH35C 48/48 63/63 * This information was not available at the time of publication.
• Pair Application, Inverter Controlled Unit • R-410A • RXH20-25-35CVMB Installation RXH20,25,35C Outdoor unit installation drawings Wrap the installation pipe with the finishing tape from bottom to top Model 20 / 25 / 35 class Max. allowable length Heat pump: 15m Max.