MONITOR HEATING SYSTEM
Section 1: Description IGFSSOO
1-14 IGNITION PLUG UNIT
The Electrode is applied high voltage, and
discharges to the Grounding Rod to ignite the
burner. The discharge gap between the Electrode
and the Grounding Rod is 1/8"±1/32" (3.5mm±0.
8mm).
Flame Detector Rod
Electrode
Grounding Rod
1
/8"±
1
/32"
(3.5mm ±0.8mm)
Figure 1-8
1-15 IGNITION TRANSFORMER
The Ignition transformer generates high voltage
using 120 VAC power, discharged by the Ignition
plug to ignite the burner.
120VAC
Power
Terminal
*
*
r
I N
High Tension Cord
-
Grounding Terminal
Figure 1-9
/!\ WARNING:
Oo not touch when functioning. High voltage of
15 kV is generated.