Ignition Plug Unit (Gf1800); Ignition Transformer (Gf1800) - Monitor GF3800 Servise Manual

Vervice heating system
Hide thumbs Also See for GF3800:
Table of Contents

Advertisement

MONITOR HEATING SYSTEM
Section 1: Description IGFISOOI
1-16 IGNITION PLUG UNIT
The Electrode is applied high voltage, and
discharges to the Grounding Rod to ignite the
burner. The discharge gap between the Electrode
and the Grounding Rod is 1/8"±
1
/32" (3.5mm±0.
8mm).
Flame Detector Rod
1
/8"±
1
/32"
(3.5mm ±0.8mm)
Electrode
Grounding Rod
1-17 IGNITION TRANSFORMER
The Ignition transformer generates high voltage
using 120 VAC power, discharged by the Ignition
plug to ignite the burner.
Power
Terminal
i
/!\ WARNING:
Do not touch when functioning. High voltage of
15 kV is generated.
Figure 1-10
m
:*
i*
if*
High Tension Cord
Grounding Terminal
Figure 1-11