1.6.3.5. CLOCK RANGE (When ANALOG is input)
This adjustment is normally unnecessary since optimum value is automatically selected
when H.TOTAL is changed.
If the jitter noise cannot be improved by H.TOTAL and FINE adjustment, CLOCK RANGE fine
adjustment may improve it.
[Procedure]
1.
Select CLOCK RANGE in the menu 1.
2.
Adjust to eliminate the jitter noise by left/right buttons.
1.6.3.6. AMP GAIN (When ANALOG is input)
Used to adjust the gain of analog signal input level as needed. It is available for each input
memory.
[Procedure]
1.
Display full-white signal via actual input route.
2.
Select AMP GAIN in the menu 1.
3.
Select AUTO GAIN and press [ENTER] button in reply to "AUTO GAIN START?" message.
The adjustment will finish when "CALCULATE..." indication disappears.
[When "ERROR" is displayed]
The error message is displayed if the input signal level exceeds the adjustment range like the
level is too low or too high, or full-white signal is not input. In such cases, it is necessary to input
signal with optimum level.
[Manual adjustment]
Normally AUTO GAIN adjustment is recommended. In special case such as full-white video
signal cannot be input, the manual adjustment may be helpful.
1.
Select AMP GAIN in the menu 1.
2.
Select MANUAL GAIN.
3.
Adjust R/G/B-GAIN or R/G/B-LEVEL respectively.
[NORMAL] button can reset it to the AMP GAIN value in the system memory (chapter 1.5.5.2,
on page 30). If it has not been set, the value is reset to the factory setting.