During lamp position auto calibration (for VS-50XLW20U) and initial sensor value
obtaining, the operating status is noticed by figures such as "3", "4" or "7". When
the function has worked correctly, it disappears after 5-minute displaying.
2.
Input port: Displaying current input port.
3.
Comment:
"NO SIGNAL" is displayed when any image signal is not input.
"TEST *" is displayed during internal test pattern displaying.
"MUTE" is displayed during picture mute.
4.
Set ID: Displaying set ID.
1.5.1.3. Basic menu operation
Adjustments should be conducted by means of the remote control in advanced mode.
[MENU1] button displays menu 1.
[MENU2] button displays menu 2 while the input board is attached. Press and hold the
[MENU2] button to display the system memory menu.
If you select an item in the menu 1 or 2 and press [ENTER] button, you can adjust each item.
Some items indicate the lower menu layer.
Up/down button selects menu item. Left/right button changes selected value.
If you press [NORMAL] button in the adjusting item, the message "RESET OK?" appears
and it resets adjustment values after pressing [ENTER] button. By [ESC] button, you can exit
the menu without resetting.
[FUNC] button allows remote ID setting. See chapter 1.5.1.4 for details.
[TEST] button can select the test patterns. See chapter 2.3, on page 69 for details. Even if
any menus are being displayed on screen, the remote ID setting is available.
[R][G][B] buttons can turn on/off the color mute. It is not available in a few test patterns.
If 3-digit number is input by number buttons [1] to [0] while there is no menu on screen, the
display memory can be called directly. For instance, press 001 to call display memory 1.
[DISPLAY] button shows status information.
LAMP TIMER
INPUT
SYSTEM ID
LAMP A NEW
LAMP B USED
NO SIGNAL
Status information ([DISPLAY] button)
1.5.1.4. Remote ID
Remote ID is used to operate the remote control toward specific screens in a multi-screen
system. Even if any menus are being displayed on screen, remote ID is selectable.
Remote ID can be designated the set ID, which is set in dipswitch, by 2-digit number in advanced
mode. For instance, if the set ID is one, input 01. It can be also selected by left/right button after
the [FUNC] button. The projector other than designated ID will ignore the remote control.
Pressing 00 after [FUNC] button enables remote control of all projectors regardless of the remote
ID setting.
VS-50XL20U, VS-67XL20U, VS-50XLW20U
Set-up and Installation Manual
Lamp operating time
99999H
Input port
ANALOG
Set ID
01
BUSY
STANDBY
Lamp status
Comment
(For
VS-50XLW20U)
20
! ANALOG
ID01
F/W VER
P01.50A
H/W VER
12.19
SET TIMER
99999H
MASTER
L.SENSOR
125
Detail status information
([DISPLAY] button press-and-hold)
Firmware version
FPGA version
Set operating time
Master/slave setting
Luminous sensor value