Mechanical Instructions - Philips 150B1C/00 Servise Manual

Lcd colour monitor
Table of Contents

Advertisement

150B LCD
12
Go to cover page
0. General
To be able to perform measurements and repairs on the "circuit
boards". these units should be placed in the service position first.
1. Removing the Back Cover
Step 1: Use a coin to pry open the clips on each side of the unit as
shown in Fig. 1.
Step 2: Hold the LCD monitor, then use the other hand to pull out the
back cover. Remove the plastic Cap from the hinge.
Fig. 1
I n s e r t a t
45° angle
Press & twist
Fig. 2
2. Removing the Bezel
Step 1: Disconnect the AC/DC power cord, VGA signal cable if
necessary.
Step 2: Remove the 2 screws (see Fig. 3).
Step 3: Release the bezel by using an optional tool (3138 106
10076) as shown in Fig. 4 and pry open (see Fig. 5) the 4
clips (see Fig. 3).
Step 4: Remove the bezel as shown in Fig. 6.
Fig. 3
Clips
Back

Mechanical Instructions

45 °
screws
Fig. 4
Fig. 6
Remove the bezel
3. Removing the Middle Cover
Step 1: Remove the 4 screws for middle cover on front side of the
units (see Fig. 7).
Step 2: Face to the rear of the monitor, then remove the 2 screws for
the Hing Pivot (see Fig. 8) to separate the Panel set from the
Base.
step 3: Place the Panel set on a soft and plain surface and remove
the middle cover.
Fig. 7
screws
(for middle
cover assembly)
Fig. 8
Middle Cover
Clips
Hinge Pivot
Fig. 5
screws
screws
Forward

Advertisement

Table of Contents
loading

Table of Contents