• SCSI Messages. The following SCSI messages are supported:
Code
Length
Message
(hex)
(bytes)
00
1
Conunand Complete
01
22
Extended Message to Follow
The following extended message is supported:
01
3*
Request for SDTR
03
2*
Wide Data Transfer Request
* added length in bytes
00
1
Abort Tag
02
Save Data Pointers
04
1
Disconuect
05
1
Initiator Detected Error
06
1
Abort
07
1
Message Reject
08
1
No Operation
09
1
Message Parity error
OA
Linked Command Complete
OB
Linked Command Complete With Flag
OC
1
Bus Device Reset
OD
1
Abort Tag
OE
1
Clear Queue
20
2
Simple Queue Tag
21
2
Head of Queue Tag
22
2
Ordered Queue Tag
80-FF
1
Identify
Notes:
1. In
=
Target to Initiator; Out
=
Initiator to Target.
2. 2nd byte indicates additional length of extended message .
• Status Codes. The following status byte codes are supported:
DRAFT
1/18/93 09:58
Code
(hex)
00
02
08
10
18
28
Status
Good
Check Condition
Busy
Intermediate
Reservation Conflict
Queue Full
Direction!
In
In/Out
In/Out
In/Out
Out
In
In
Out
Out
In/Out
Out
Out
In
In
Out
Out
Out
In/Out
Out
Out
In/Out