    1.0 INTRODUCTION Thank you for purchasing a Heatrae Sadia UTC 99 vented water heater. The UTC 99 water heater is manufactured in the UK to the highest standards and has been designed to meet all the latest relevant safety specifications.
  • Page 3: Technical Specification

    Means for disconnection from the supply mains having a con- tact seperation in all poles that provide full disconnection under overvoltage category III conditions is required. The instructions shall state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. 2.0TECHNICAL SPECIFICATION Electrical rating 1.5kW@240V~ or 3kW@240V~ 50Hz.
  • Page 4: Installation

    It must not be connected to a tap. 3.1 IMPORTANT INSTALLATION POINTS 3.1.1 The UTC 99 vented water heater is designed to be fitted under a sink or worktop. 3.1.2 The UTC 99 can be installed either as an Open Outlet or Cistern Fed type unit when used with the appropriate fittings.
  • Page 5 When installed as a Cistern Fed water heater, the cold water supply must be from a feed cistern complying with Water Byelaw 30. A vent pipe must be connected to the outlet of the heater. The vent pipe must rise continuously and be arranged to discharge into the cold water feed cistern.
  • Page 6 Heatrae Sadia. 3.2.6 Only one outlet can be served via an Open Outlet type tapset. A range of open outlet (vented) taps are available from Heatrae Sadia. All tapsets are of high quality chromium plated brass construction. PACK J...
  • Page 7 CISTERN FED INSTALLATION 3.2.10 This method of installation must be used if the outlet is to be connected to one or more conventional taps. It is not recommended for supplying a shower. Individual site demands should be considered when choosing the number of outlets to be served.
  • Page 8 3.3 ELECTRICAL REQUIREMENTS WARNING: This appliance must be earthed. It is suitable for a.c. supply only. Disconnect the electrical supply before removing the terminal cover. Electrical installation must be carried out by a competent electrician and be in accordance with the latest I.E.E. wiring regulations. Ensure the electrical supply is switched off before making any connections to the water heater.
  • Page 9: Commissioning

    4.0 COMMISSIONING Do not switch on the electrical supply until the unit has been filled with water and checked for leaks. Check that all installation and electrical requirements have been met. Check that all water and electrical connections are tight. Open a hot water tap and turn on cold water supply to the heater.
  • Page 10: Maintenance

    In hard water areas the water heater will require periodic descaling. Maintenance and servicing should be carried out by a competent person and any replacement parts used should be authorized Heatrae Sadia spare parts. 6.1 RE SETTING THE THERMAL CUTOUT 6.1.1 Switch off and disconnect the electrical supply, turn off the water supply...
  • Page 11 FIGURE 05: COMPONENT IDENTIFICATION 6.2 DRAINING THE WATER HEATER 6.2.1 Switch off and disconnect the electrical supply. Turn off the water supply to the unit. 6.2.2 Open a hot tap to relieve any system pressure. Disconnect the plumbing connections to the unit and remove (note full weights of units). Empty unit through the outlet connection.
  • Page 12: Fault Finding

    The water heater should give trouble free operation, however should a problem occur, the table overleaf should enable most faults to be identified with ease. Fault Finding should be carried out by a competent person and any replacement parts used should be authorised Heatrae Sadia spare parts.
  • Page 13 2. Vent pipe blockage 2. Check vent pipe for obstructions, clear as necessary. NOTE: Use only Heatrae Sadia approved spare parts. Replacement of any parts with components not recommended by Heatrae Sadia will invalidate the guarantee and may render the installation dangerous.
  • Page 14: Spare Parts

    To ensure the continued safe and efficient operation of the water heater it should be regularly maintained. Maintenance and servicing should be carried out by a competent person and any replacement parts used should be authorized Heatrae Sadia spare parts. DESCRIPTION CODE No.
  • Page 15: Guarantee

    This Guarantee in no way affects the statutory rights of the consumer. The policy of Heatrae Sadia is one of continuous product development and, as such, we reserve the right to change specifications without notice. 10.0 ENVIRONMENTAL INFORMATION Heatrae Sadia products are manufactured from many recyclable materials.
  • Page 16: Spares Stockists

    Almonsbury, Bristol, BS32 4TF Tel: 01454 620500 Alternatively contact your local supplying merchant or wholesale branch or use our online stockist finder at www.interpartspares.co.uk AFTER SALES SERVICE t| 0344 8711535 e| customer.support@heatraesadia.com Heatrae Sadia Hurricane Way Norwich NR6 6EA www.heatraesadia.com 36005721_issue_03...