Control Lever Removal

IMPORTANT: Refer to Trim/Tilt Switch Wire
Routing. Route trim/tilt wiring carefully when re-
mote control lever and trim/tilt switch wiring are
repositioned.
Refer
to
Remote
Diagrams before performing the following steps.
Remove back control cover. Compress tabs of
trim wire cover to remove cover. Remove cover
(standard configuration) and trim wire and
retainer from remote control.
2
1. Trim/tilt wire cover
2. Retainer
Loosen control lever retaining screw (12 mm)
three to four rotations counterclockwise.
1. Lever retaining screw
Support the remote control housings. Strike the
screw head with a center punch and hammer to
unseat control lever.
12 of 24
Control
Configuration
004868
004875
004874
Remove the screw and washer. Detach remote
control lever and joint from remote control. Place
flat tip screwdriver in notch of joint to pry from
control.
3
1. Lever
2. Joint
3. Notch
Loosen and remove two screws and neutral lock
1
plate from remote control housing.
1
Position neutral lock plate on appropriate side of
remote control housing. Install two screws with
lock washers through plate and torque screws to
35 in. lbs. (4 N·m).
2
1
004878
004911
004876
004877