40MB*F / 38MAQ
Floor Console Ductless Split System
Sizes 09 to 12

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
A PERFECT BALANCE BETWEEN
BUDGET LIMITS, ENERGY SAVINGS AND
COMFORT.
The 38/40MBF series ductless split systems are a matched
combination of an outdoor condensing unit and an indoor fan coil
unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the floor, against the wall. This
selection of fan coils permits creative solutions to design problems
such as:
S
S
S
S
S
The ideal compliment to your ducted system when it is
impractical or prohibitively expensive to use ductwork.
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors. Advanced system
components incorporate innovative technology to provide reliable
cooling performance at low sound levels.
Add- -ons to current space (an office or family room
addition)
Special space requirements
When changes in the load cannot be handled by the
existing system.
When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork.
Historical renovations or any application where
preserving the look of the original structure is essential.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 38MAQB12 Series and is the answer not in the manual?

Questions and answers

Summarization of Contents

Product Data
Industry Leading Features / Benefits
Highlights the key advantages and operational benefits of the ductless split system.
A Perfect Balance Between Budget Limits, Energy Savings and Comfort
Emphasizes the system's optimal blend of cost, energy efficiency, and user comfort.
Model Number Nomenclature
Indoor Unit Model Number Breakdown
Explains the coding system used for indoor unit model numbers.
Outdoor Unit Model Number Breakdown
Details the coding system used for outdoor unit model numbers.
Standard Features and Accessories
Indoor Unit Standard Features
Lists standard features for indoor units, covering installation and comfort.
Outdoor Unit Standard Features
Details standard features and installation aspects of outdoor units.
Available Accessories
Lists optional accessories for system customization and installation flexibility.
Dimensions
Indoor Unit Dimensions
Provides detailed measurements (height, width, depth) for the indoor unit.
Outdoor Unit Dimensions
Provides detailed measurements (width, depth, height) for the outdoor unit.
Clearances
Indoor Unit Clearance Requirements
Specifies required clearance space around the indoor unit for optimal airflow.
Outdoor Unit Clearance Requirements
Specifies minimum clearance space around the outdoor unit for proper airflow.
Specifications
System Performance Specifications
Details cooling/heating capacity, SEER, HSPF, and electrical ratings.
Compressor and Coil Specifications
Provides details on compressor type, oil, and coil construction.
Performance Data
Cooling Performance Tables
Presents cooling capacity and input power data under various conditions.
Heating Performance Tables
Presents heating capacity, input power, and COP data under various conditions.
Application Data
Unit Selection Guidelines
Provides guidance on selecting the appropriate unit for peak load and comfort.
System Operating Conditions
Defines the operating and non-operating temperature ranges for the system.
Refrigerant Line Sizing and Installation
Details guidelines for refrigerant line sizing, insulation, and long line applications.
Wiring and Controls
Wiring Requirements
Specifies requirements for power and communication wiring per NEC/CEC codes.
Control System Functionality
Explains the microprocessor control system and its functions for safety and comfort.
Remote Control Operation
Describes the wireless remote control for system operation and settings.
Detailed Technical Data
Air Flow and Sound Data
Provides airflow rates and sound pressure/power levels for units.
Electrical Data
Lists electrical parameters including voltage, current, MCA, and fuse ratings.
Fan and Motor Specifications
Indoor Fan and Motor Details
Provides specifications for the indoor fan, including type, size, and motor details.
Outdoor Fan and Motor Details
Provides specifications for the outdoor fan, including type, size, and motor details.
Wiring Diagrams
Indoor Unit Wiring Connections
Illustrates the wiring diagram and component connections for the indoor unit.
Outdoor Unit Wiring Connections
Illustrates the wiring diagram and component connections for the outdoor unit.
Guide Specifications
Part 1 - General Information
Covers system description, agency listings, delivery, storage, and warranty.
Part 2 - Indoor Unit Products
Details indoor unit equipment, cabinet, fans, coil, motors, and controls.
Guide Specifications - Outdoor Unit
Part 1 - General Information
Covers system description, agency listings, delivery, storage, and warranty.
Part 2 - Outdoor Unit Products
Details outdoor unit equipment, cabinet, fans, compressor, coil, and controls.