HIKVISION 9600 Series User Manual page 64

Table of Contents

Advertisement

Pre-record: The time you set to record before the scheduled time or event. For example, when an
alarm triggered the recording at 10:00, if you set the pre-record time as 5 seconds, the camera
records it at 9:59:55.
Post-record: The time you set to record after the event or the scheduled time. For example, when
an alarm triggered the recording ends at 11:00, if you set the post-record time as 5 seconds, it
records till 11:00:05.
Expired Time: The expired time is the longest time for a record file to be kept in the HDD, if the
deadline is reached, the file will be deleted. You can set the expired time to 0, and then the file will
not be deleted. The actual keeping time for the file should be determined by the capacity of the
HDD.
Redundant Record/ Capture: Enabling redundant record or capture means you save the record
and captured picture in the redundant HDD. See Chapter Configuring Redundant Recording and
Capture.
Record Audio: Check the checkbox to enable or disable audio recording.
2)
Click Apply to save the settings.
Note:
The redundant record/capture is to decide whether you want the camera to save the record files or
captured pictures in the redundant HDD. You must configure the redundant HDD in HDD settings. For
detailed information, see Chapter 11.4.2 Setting HDD Property.
Note:
The parameters of Main Stream (Event) are read-only.
3. Encoding Parameters Settings for Sub-stream
1)
Enter the Sub-stream tab page.
2)
Configure the parameters of the camera.
3)
Click Apply to save the settings.
4. Encoding Parameters Settings for Capture
1)
Select the Capture tab.
2)
Configure the parameters.
3)
Click Apply to save the settings.
User Manual of 9600/8600/7700/7600 Series NVR
Figure 5. 4
Sub-stream Encoding
Figure 5. 5
Capture Encoding
64

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8600 series7700 series7600 series

Table of Contents