Location Requirements - KitchenAid KUDE20FB*0 Technical Education

2013 stainless steel tall tub dishwasher *all colors
Table of Contents

Advertisement

Grounded electrical supply required.
Do not run drain lines, water lines or electrical wiring where they
can interfere with or contact dishwasher motor or legs.
The location where the dishwasher will be installed must provide
clearance between motor and flooring. Motor should not touch
the floor.
Do not install dishwasher over carpeted flooring.
Shelter dishwasher and water lines leading to dishwasher against
freezing. Damage from freezing is not covered by the warranty.
A side panel kit is available from your dealer for installing your
dishwasher at the end of your cabinetry.
A moisture barrier accessory (Part Number 4396277) is available
from your dealer for installing underneath the countertop.
Call 1-800-422-1230 to order.
4

Location Requirements

Location Requirements
KitchenAid 2013 Stainless Steel Tall Tub Dishwasher
Check location where dishwasher will be installed. The location
must provide:
easy access to water, electricity and drain.
I
convenient access for loading and unloading dishes.
I
Corner locations require a 2" (5.1 cm) minimum clearance
between the side of the dishwasher door and the wall or
cabinet.
square opening for proper operation and appearance.
I
cabinet front perpendicular to floor.
I
level floor. (If floor at front of opening is not level with floor
I
at rear of opening, shims may be needed to level
dishwasher.)
Helpful Tip: Be sure to accurately measure dimensions and
ensure dishwasher is level if the floor in the dishwasher opening is
uneven (example: Flooring extends only partway into opening).
NOTE: To avoid shifting during dishwasher operation, shims must
be securely attached to the floor.
If dishwasher will be left unused for a period of time or in a
location where it may be subject to freezing, have it winterized by
authorized service personnel.
Make sure pipes, wires and drain hose are within the shaded area
shown in the "Product and Cabinet Opening Dimensions" section.