OPERATING INSTRUCTIONS 
The MCP59 has an electronic touch control 
panel in the upper right hand corner. 
Before turning unit on, ensure unit is plugged 
in, water supply to pump is on, and there is 
correct ventilation, as shown on page 3 of this 
manual. 
 
Note: These units may be controlled using the 
3 buttons on the front panel of the cooler or 
with the remote control. 
 
On/Off  
This button initiates power to the unit. When 
first plugged, pressing ON/OFF will start the 
unit in the default setting (pump ON and Fan 
on HIGH).  After its initial use, the last 
operating settings (for fan and pump) will be 
reinstated when the unit is turned on again.   
Pressing this button when the unit is already running will turn both fan and pump off.  
After A Power Failure:  Once power is restored, the unit will restart in the same settings as before power was 
lost. 
 
Pump  
This button toggles the pump on and off. When the LED is lit, the pump is running.  
The pump must be on while operating the fan for the unit to operate as an evaporative cooler, though the unit 
can be used in fan mode without the pump, if desired. 
Note: For best results turn on the pump for a few minutes to wet the pads before operating the fan.  
 
Fan 
Pressing the fan button cycles the unit from HIGH, to MEDIUM to LOW speeds and then OFF. 
Please Note: There is a two second delay from the pressing of the button for the fan to engage or change 
speeds. This applies to the front control panel and the remote control. 
Remote Control 
The remote control supplied with this cooler allows you to turn the unit on 
or off, control fan speed and initiate the pump. The buttons operate in the 
same manner as those on the front control panel. 
The remote control's range is approximately 20 feet within sight of the 
cooler. It uses two AA alkaline batteries (included). A wall mountable 
holder is also supplied with the cooler. 
 
 
Fan Speeds:
Power
 
 
FAN
HI MED LO
off
on
PUMP
Indicator
Lights
UNIT POWER ON/OFF
PUMP ON/OFF
FAN SPEED (1-3)
ON
PUMP
FAN
CHAMPION / ESSICK AIR
Water Pump
On/Off
 
 

Hide quick links: