MasterCool MCP59 Installation And Operating Manual page 6

Table of Contents

Advertisement

Available languages

Available languages

SHUT OFF VALVE
PLASTIC OR
COPPER LINE
TO COOLER
STD. HOSE CONNECTION
Water Pump and Lines 
A self‐contained water pump continuously 
circulates water through the water distribution  
system and over the media.
The pump and water lines are shipped unconnected
MAIN
 
WATER
LINE
JUNCTION
OVERFLOW
DRAIN
FITTING
REMOVE NIPPLE FROM
TUBE BEFORE FEEDING
IT INTO DRAIN OVERFLOW.
REINSTALL NIPPLE INTO
OVERFLOW LINE
(AFTER
INSERTING
LINE THROUGH
OVERFLOW
FITTING)
NIPPLE
Overflow Drain 
1. Slide the rubber washer over the overflow fitting  and push through the hole in the bottom of the cooler from 
the top side.  
2. Secure the drain from beneath the pan with the Lock Nut.  
Make sure the rubber washer does not twist while tightening, 
which could cause it to leak.  DO NOT OVERTIGHTEN. 
3. If leakage occurs after reservoir is full, retighten the overflow fitting until 
leaking stops. A small amount of silicone caulk may be used if necessary. 
4. Attach a drain hose to the bottom of the fitting if necessary.  
Water Connection   
NOTE:  A standard sillcock with water valve attached (locally available) will 
be required to connect the water supply to the cooler. 
1. Steady water supply is required for operation of the cooler. If taking water 
from an external water faucet, install a sillcock and shutoff valve.  
2. Install plastic or copper line to sillcock and connect it to the float valve. 
 
SILLCOCK
 
 
 
 
Connect the Water Lines
1. Locate the black water line snapped into plastic  
  keepers inside the unit. 
PUMP
2. Attach the bottom end of the main water line to  
(STRAINER NETTING
NOT SHOWN
  the pump inlet. 
FOR CLARITY)
PUMP
3. Remove the nipple inserted into the end of the 
INLET
     overflow line. Push overflow hose into one of the   
   slots in the sides of the overflow drain fitting. 
4.   Reinsert the nipple into the overflow line. 
5. Attach the top of the hose to the water distribution tray. 
6. Ensure there are no kinks in the water lines after 
  completion
 
 
WATER LEVEL
 
 
Water Level 
Two inches of water 
should be maintained 
in the bottom of the cooler to ensure sufficient water 
for correct operation of the cooler.
The float is factory‐installed to maintain a 2 inch 
level of water, but may require adjustment if shipping 
or installation has caused the setting to shift. 
 
FLOAT VALVE
WATER LINE
ATTACH POINT
 
 

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents