Installation in Window
4" MINIMUM
SCREW
SPACER TO ENSURE
FLUSH/SQUARE
INSTALLATION
(NOT SUPPLIED)
2. Closing the window may help hold the unit in place during the following steps – Push the unit into the window
until the bottom is flush with the outside wall or spacer (not supplied) as shown in the illustration.
3. Make sure unit is level. From the interior, locate the two tracks on the bottom of the fan assembly. Drill
pilot holes as necessary and install the two window sill brackets as shown in illustration.
4. Secure the top of the fan housing to the window frame with two additional brackets and screws.
5. From the outside, secure the unit to the exterior
wall (or spacer) with two screws at the base of the
back cover (as shown in illustration.) Complete the
installation of the exterior portion with two screws
at the top of the back media guard.
6. With the unit now installed in the window, attach
one accordion spacer to each side of the fan
assembly using the adhesive backed edges. Short
screws (not included) can be used for a more
secure installation. (Make sure screws do not
interfere with fan blade)
7. Once accordion spacers are installed, seal any gaps
around the units with silicone or all weather caulk (not supplied).
Installation in Wall
This cooler is approved for in‐wall installation. Contact a licensed contractor for having the cooler installed in an
outside wall.
"
33
5
/
8
5
"
21
/
8
5
"
21
/
8
1
"
46
/
8
FRONT VIEW
WINDOW
OPTIONAL MOUNTING
2 PLACES -
MINIMUM 14" APART
SCREW
WINDOW
WINDOW SILL
SCREWS
WINDOW SILL BRACKET
WINDOW SILL
3
"
9
/
4
"
5
" 10
3
/
12
/
16
8
1. Remove screen ( as needed) and make sure
window is opened to its maximum height.
From the exterior of the window, slide the fan
assembly section into the window. Have the
person on the interior adjust the exact
placement of the unit for aesthetics and
correct lengths of the two accordion spacers
(included).
Note: After identifying the position for
installation, place a bubble level on top of the
unit and make adjustments to ensure the unit
will be level when installation is complete. It is
recommended to verify unit is level at various
points during installation.
5
"
33
/
8
13
"
19
/
16
5
"
21
/
8
SCREWS
TOP VIEW
SPACER TO ENSURE
FLUSH/SQUARE
INSTALLATION
(NOT SUPPLIED)
5
4" MINIMUM
SCREW
SILL BRACKET
SILL PLATE
SCREWS