Charging Procedure

Note: Battery charger and battery packs are not
included in the delivery scope. The power plug
shown can vary from the one on your power tool.
Please take care, that the charger and the
battery pack are suitable for your country
specific electricity network.
15 Minute Charger AL 15 FC (see figure A)
Plug the power plug 12 of the battery charger 11
into your electrical power supply outlet and in-
sert the battery 5 correctly into the charging
compartment of the battery charger.
Do not exert any force when inserting/
removing the battery. Batteries with APT
contact (Akku Pack Top) are designed in
such a manner that they can only be inserted
into the power tool or the charger in the
correct position.
The green LED indicator 13 starts to flash. This
indicates the flow of the charging current. The
charging process automatically stops when the
battery is fully charged. The charging procedure
is over when the green LED indicator no longer
flashes and lights up uniformly. An audible sig-
nal sounds for approx. 2 seconds and signals
that the battery is fully charged.
Continuous lighting of the red LED indicator 14
signals a charging procedure with reduced
charging current. When the red LED indicator
flashes, charging is not possible.
1 Hour Charger AL 60 DV (see figure B)
Plug the power plug 12 of the battery charger 11
into your electrical power supply outlet and in-
sert the battery 5 correctly into the charging
compartment of the battery charger.
Do not exert any force when inserting/re-
moving the battery. Batteries with APT con-
tact (Akku Pack Top) are designed in such a
manner that they can only be inserted into
the power tool or the charger in the correct
position.
Bosch Power Tools
The green LED indicator 13 starts to flash. This
indicates the flow of the charging current. The
charging process automatically stops when the
battery is fully charged. The charging procedure
is over when the green LED indicator no longer
flashes and lights up uniformly.
Continuous lighting of the green LED indicator
13 signals that charging is not possible.
Troubleshooting – Causes and Corrective
Measures
Cause
Corrective Measure
LED indicators do not light up
Mains plug of battery
Insert mains plug
charger not plugged in
(fully) into the socket
(properly)
outlet
Socket outlet, mains
Check the mains volt-
cable or battery charg-
age; have the battery
er defective
charger checked by an
authorised after-sales
service agent for
Bosch power tools
No charging procedure possible
Temperature of bat-
Increase or reduce the
tery pack not within
battery pack tempe-
the specified range
rature to within the
specified range be-
tween 0 °C (32 °F)
and 45 °C (113 °F)
Battery contacts con-
Clean the battery con-
taminated
tacts (e.g. by inserting
and removing the bat-
tery several times) or
replace the battery
Battery defective
Replace the battery
Battery not inserted
Insert battery (fully)
(properly)
into the battery charg-
ing compartment
3 609 929 B57 | (5.12.07)