(7) Operation Details

• Soft Dry Operation Mode
When the room temperature is higher than the set temperature, it operates cooling mode, the set fan
speed (if AUTO mode, then med.), and then it will switch to Soft Dry Operation Mode when the room
temperature reaches the set temperature.
In Soft Dry Operation Mode, the indoor fan speed is automatically switched to low.
SET TEMP. +1°C
SET TEMP. -0.5°C
INDOOR
FAN
COMP.
OPERATING START
• Auto Air
For fresh cooling more than other modes.
Press the Indoor Fan Speed Selector and set to Auto Air mode.
The Air flows from medium to low speed, or reversely by the room temperature.
The set temperature goes up by time automatically.
This mode economizes power consumption and prevents over-cooling (below Fig).
COOLING
ROOM
TEMP
SET
FAN
SPEED
OPERATE
1HOUR
AUTO AIR MODE OPERATION
ROOM TEMP.
SOFT DRY
¡ªLOW COOL
OPERATION
OPERATE
FOR
10MINS
STOP
STOP
FOR
FOR
7 MINS
7 MINS
Room Temp.
0.5°C
0.5°C
1
1 /
HOUR
2
— 19 —
¡ªLOW COOL
OPERATION
OPERATE
FOR
10MINS