Download Print this page

Temperature Adjustment - OSO Super S Installation And User Manual

Hide thumbs Also See for Super S:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
Pipe fitting
Pipe fitting - mixing valve
Mixing valve:
The Super S is fitted
with a UX
valve.
The valve
is factory
fitted, simp-
ly adjust to
required angle
and tighten nut.
Overflow pipe from safety valve
-must be fitted in rooms where a gully is not available
Optional rearwards
Power cable
Hw Cw
360°
If the safety valve
is to be adjusted
the nut must first
be loosened. Al-
ways remember
to tighten nut
after adjustment.
Subject to changes without notice
Hw
mm
Mixing valve
Packing box

Temperature adjustment

The water temperature from the water heater to
the taps is adjusted with wheel A.
Start by turning A fully counter-clockwise. Then
adjust to requested temperature according to
the diagram below by turning A clockwise.
The water inside the unit will, regardless of valve adjustment,
maintain a temperature of approx. 70-75°C to prevent bacteria.
°C
75
70
65
60
55
50
45
40
35
30
25
0
SVK
9 bar
Power cable and/
or overflow pipe
3/4"R
(optional)
Overflow
pipe ø18
mm internal
(not included)
Pull out
Optional
downwards
Power cable and/
or overflow pipe
(optional)
Cw
ø 15 mm pipe
Cu or PEX
45
w/approved fittings
Nut
Olive
1/2" R thread
1
2
Bottom view
Spår
Eng
-
Off
A
+ On
UX
3
Turns clockwise
Adjustable feet
Overflow
straight
down
(optional)
17

Advertisement

loading

This manual is also suitable for:

Super sxSuper scSuper sa