LIGHTING MODE OF THE SELF-DIAGNOSIS LAMP
MODEL RAC-50WX8, RAC-D18EX3
CUT  THE  POWER
SOURCE  AND  WAIT
MORE  THAN  10
MINUTES  BEFORE
SERVICE  WORK.
CONFIRM  THE  DC
VOLTAGE  AT  THE
MEASURING  POINT
SHOWN  IN  FIGURE
MUST  BE  LESS
THAN  10V.
DO  NOT  TOUCH  THE
SCREWS  AT  SYSTEM
POWER  MODULE  DUE
TO  HIGH  VOLTAGE.
DO  NOT  TOUCH  THE
OTHER  COMPONENTS
WHEN  OPERATING  THE
SERVICE  SWITCH.
ATTENDRE  DIX  MINUTES
APRÈS  AVOIR ÉTEINT
L'INTERRUPTEUR  DE
COURANT  QUAND
L'OPÉRATION
D'ENTRETIEN  EST
TERMINEÉ.
CONTRÔLER  QUE  LE
VOLTAGE  EST  DE
MOINS  DE  10V.  C.C.
AU  POINT  DE  MESURE.
NE  PAS  TOUCHER  LA
VIS  DU  MODULE  DE
PUISSANCE  DU  SYSTÈME
À  CAUSE  DE  SON
VOLTAGE ÉLEVÉ.
NE  TOUCHER  AUCUNE
PARTIE  SUR  LE
BOÎTIER  CONTENANT
L'INTERRUPTEUR  DE
BRANCHEMENT.
SERVICE
OPERATION
PROCEDURE  OF  REFRIGERANT  PUMP
DOWN  OR  INDEPENDENT  OPERATION
OF  OUTDOOR  UNIT.
1.  CUT  OFF  THE  POWER  SOURCE  ONCE
     THEN  ON  AGAIN.
2.  WAIT  1  MINUTE  AL  LEAST.
3.  PRESS  THE  SERVICE  SWITCH
      ( WHICH  IS  ON  THE  PWB )   MORE
     THAN  1  SECOND.
SERVICE  OPERATION  WILL  BE  STARTED.
TO  STOP  THIS  OPERATION ,   PRESS
THE  SERVICE  SWITCH  AGAIN  ( MORE
THAN  1  SECOND ) .
TO  RESUME  TO  NORMAL  OPERATION ,
CUT  THE  POWER  SOUCE  ONCE  THEN
ON  AGAIN.
IN  ORDER  TO  PROTECT  THE  DAMAGE
OF  COMPRESSOR ,   DO  NOT  OPERATE
MORE  THAN  5  MINUTES  WITH  SERVICE
VALVE  CLOSE.
DANGER
SELF-DIAGNOSIS  LIGHTING  MODE
L
(
DC400V
)
D
3
0
1
RED RED
1TIME
DANGER
2TIMES
(
)
C.C.  DE  400V
3TIMES
4TIMES
5TIMES
6TIMES
7TIMES
8TIMES
9TIMES
10TIMES
12TIMES
13TIMES
14TIMES
※EXAMPLE OF
BLINKING  (5  TIMES)
POINT  DE  MESURE
MEASURING  POSITION  OF  DC  VOLTAGE ( + )
SCREW ( DANGER  OF  ELECTRIC  SHOCK )
     
L
SELF-DI A -
D
3
GNOSI S  NAME DETAILS MAI N  CHECK POI N T
0
2
[ 1 ] DURING  OPERATION
NORMAL
COMPRESSOR
OPERATION
OPERATION
SET
(2)
OVERLOAD
(1)
VALUE
(1)
(3)
OVERLOAD
TIME
(2)
THE  ROTATION  SPEED  IS
AUTOMATICALLY  CONT-
OVERLOAD
ROLLED  TO  PROTECT  THE
(3)
COMPRESSOR  IN  THE
OVERLOAD  CONDITION.
[ 2 ] DURING  STOP
LD303 (RED) GOES  OFF.   
NORMAL
STOPPED  BY  THERMOSTAT
OR  CONTROLLER.
STOP
MICROPROCESSOR  WAS
RESET
REBOOTED.  (IT  IS  NORMAL
WHEN  POWER  SW  HAS  BEEN
STOP
TURNED  ON)
COMPRESSOR  PEAK
PEAK  CURRENT
CURRENT  WAS  BEYOND
CUT
MAXIMUM  LIMIT.
ABNORMAL
LOST  THE  COMPRESSOR
LOW  SPEED
ROTOR  POSITION.
ROTATION
SWITCHING  FROM  LOW
SWITCHING
FREQUENCY  SYNC  START
TO  POSITION  DETECTION
FAILURE
OPERATION  FAILURE.
OVERLOAD  PROTECTION
OVERLOAD
FUNCTION  IS  REQUESTING
LOWER  LIMIT  CUT
LOWER  SPEED  THAN  MINIMUM
SPEED  OF  COMPRESSOR.
COMPRESSOR  OVERHEAT
OH  THERMISTOR
WAS  DETECTED  BY
TEMP.RISE
OH  THERMISTOR.
ABNORMAL  THERMISTOR
THERMISTOR
VALUE  (OPEN  OR  SHORT)
ABNORMAL
WAS  DETECTED.
COMPRESSOR  WAS  NOT
ACCELERATION
ACCELERATED  MORE  THAN
FAILURE
MINIMUM  SPEED.
COMMUNICATIONS  BETWEEN
COMMUNICA-
INDOOR  UNIT  AND  OUTDOOR
TIONS  ERROR
UNIT  ARE  INTERRUPTED
ABNORMAL
ABNORMAL  POWER  SOURCE
WAS  DETECTED
POWER
SOURCE
OUTDOOR  FAN  RPM  IS
FAN  LOCK
NOT  ROTATE  AS  INTENDED
ERROR
RPM
EEPROM
MICROCOMPUTER  CANNOT
READ  THE  DATA  IN  EEPROM.
READ  ERROR
OVERVOLTAGE  WAS
ACTIVE  CONVERTER
DETECTED  BY
DEFECTIVE
SYSTEM  POWER  MODULE
2sec.
MEASURING  POSITION  OF  DC  VOLTAGE ( − )
SYSTEM  POWER  MODULE
HIC
CN14
CN8
CN7
CN15
WHT
CN5
CN10
CN9
SERVICE  SWITCH
– 172 –
:LIGHT :BLINK
:OFF
LD303 (RED) LIGHTS.
NOT  MALFUNCTION
THIS  SHOWS  AN
OVERLOAD  PROTECTION
STATUS.
NOT  MALFUNCTION.
NOT  MALFUNCTION.
P.W.B.
①SYSTEM  POWER  MODULE
②COMPRESSOR ③P.W.B. 
①SYSTEM  POWER  MODULE
②COMPRESSOR ③P.W.B. 
①SYSTEM  POWER  MODULE
②COMPRESSOR ③P.W.B. 
①OUTDOOR  UNIT  IS  EXPOSED  TO  DIRECT
 SUNLIGHT  OR  ITS  AIRFLOW  BLOCKED.
②FAN  MOTOR ③FAN  MOTOR  CIRCUIT
④THE  VOLTAGE  IS  EXTREMELY  LOW. 
①LEAK  OF  REFRIGERANT ②COMPRESSOR
③OH  THERMISTOR  CIRCUIT
④FAN  MOTOR ④FAN  MOTOR  CIRCUIT 
①THERMISTOR ②CONNECTION
 OF  THERMISTOR  DEFECTIVE
③THERMISTOR  CIRCUIT 
①LEAK  OF  REFRIGERANT
②COMPRESSOR
①CABLE  IS  WRONG  CONNECTED
②CABLE  IS OPEN ③INTERFACE
 CIRCUIT  OF  BETWEEN  INDOOR
 UNIT  AND  OUTDOOR  UNIT 
①ABNORMAL  POWER  SOURCE
②CABLE  IS  WRONG  CONNECTED
③SYSTEM  POWER  MODULE
④P.W.B.
①FAN  MOTOR
②FAN  MOTOR  CIRCUIT
P.W.B.
SYSTEM  POWER  MODULE
‥LIGHTS FOR 0.25
SEC  AT  INTERVAL
OF  0.25  SEC.
P.W.B.
N
YEL
BLU
GRN2
RED
BRN
CN2
RED
GRN1
BLK
WHT
LD301
LD302
LD303