Hitachi RAS-S10CY Instruction Manual
Hitachi RAS-S10CY Instruction Manual

Hitachi RAS-S10CY Instruction Manual

Split type indoor unit/outdoor unit
Hide thumbs Also See for RAS-S10CY:

Advertisement

INDOOR UNIT/OUTDOOR UNIT
OUTDOOR UNIT
RAC-S10CY
RAC-5115CY
RAC-S13CY
Instruction manual
To obtain the best performance and ensure years of trouble free use, please read this instruction manual
completely.
Arahan pengendalian
Untuk mendapatkan prestasi yang tinggi dan mengelakkan masalah untuk jangka masa yang lama, sila baca arahan
ini sepenuhnya.
Hướng dẫn sử dụng
Hướng dẫn sử dụng
Để máy hoạt động tốt nhất, và để đảm bảo máy sử dụng được lâu năm mà không gặp sự cỐ, bạn hãy đọc thật kỹ
hướng dẫn sử dụng này.
(EN) Cover S10CY 1
(EN) Cover S10CY 1
MODEL
RAS-S10CY/RAC-S10CY
RAS-5115CY/RAC-5115CY
RAS-S13CY/RAC-S13CY
– 1 –
INDOOR UNIT
RAS-S10CY
RAS-5115CY
RAS-S13CY
Muka surat 23~44
Trang 45-66
Page 1~22
1/6/09 9:39:09 AM
1/6/09 9:39:09 AM

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi RAS-S10CY

  • Page 1 INDOOR UNIT/OUTDOOR UNIT MODEL RAS-S10CY/RAC-S10CY RAS-5115CY/RAC-5115CY RAS-S13CY/RAC-S13CY OUTDOOR UNIT INDOOR UNIT RAS-S10CY RAC-S10CY RAS-5115CY RAC-5115CY RAS-S13CY RAC-S13CY Instruction manual Page 1~22 To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely. Arahan pengendalian...
  • Page 2: Safety Precaution

    SAFETY PRECAUTION Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit. Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly.
  • Page 3 PRECAUTIONS DURING OPERATION The product shall be operated under the manufacturer specification and not for any other intended use. Do not attempt to operate the unit with wet hands, this could cause fatal accident. When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.
  • Page 4: Names And Functions Of Each Part

    Condensed water drain to outside. Connecting cord and insulation pipe for piping Air inlet (Back, Left side) Air outlet MODEL NAME AND DIMENSIONS MODEL WIDTH (mm) HEIGHT (mm) DEPTH (mm) RAS-S10CY/RAS-5115CY/RAS-S13CY RAC-S10CY/RAC-5115CY/RAC-S13CY – 4 – (EN1) S10CY/5115CY/S13CY 1/6/09, 9:16 Black...
  • Page 5 INDOOR UNIT INDICATORS FILTER LAMP When the device is operated for a total of about 100 hours, the FILTER lamp lights to indicate that it is time to clean the filter. The lamp goes out when the POWER SWITCH set to OFF and ON again. OPERATION LAMP TEMPORARY This lamp lights during operation.
  • Page 6: Names And Functions Of Remote Control Unit

    NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT REMOTE CONTROLLER This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is controlled electronically, the range of control may be shorter. This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can be controlled from the remote controller.
  • Page 7: Cooling Operation

    COOLING OPERATION Use the device for cooling when the outdoor temperature is 21-43°C. If humidity is very high (over 80%) indoors, some dew may form on the air outlet grille of the indoor unit. Press the button so that the display indicates (COOL).
  • Page 8: Dehumidifying Operation

    DEHUMIDIFYING OPERATION Use the device for dehumidifying when the room temperature is over 16°C. When it is under 15°C, the dehumidifying function will not work. Press the (DEHUMIDIFY) button. Dehumidifying operation starts with a beep. The FAN SPEED is set at LOW automatically. The FAN SPEED button does not work.
  • Page 9: Circulation Operation

    CIRCULATION OPERATION Press the button so that the display indicates (CIRCULATE). Circulating operation starts with a beep. Press the FAN SPEED button and select the desired FAN SPEED (the display indicates your choice). Press the temperature control button to set to the desired temperature.
  • Page 10: Super Cooling

    SUPER COOLING Press the button. Operation start with a signal received sound “beep”. Unit will be forced operate in (COOL) with SUPER COOL fan speed for 20 minutes. Indicator appear during this period while temperature and fan speed setting display remain unchanged.
  • Page 11 HOW TO SET THE SLEEP TIMER Press the (SLEEP) button, and the display changes as shown below. Mode Indication 1 hour 2 hours 3 hours 7 hours Sleep timer Sleep timer off Sleep Timer: The device will continue working for the designated number of hours and then turn off.
  • Page 12: How To Set The Timer

    HOW TO SET THE TIMER I ON Timer and OFF Timer are available. I Operation stop at setting time OFF Timer Reservation OFF TIME setting Select the OFF TIME by pressing the (OFF) Button. Setting time will change according to the below sequence when you press the button.
  • Page 13: Air Flow Louvers Adjustments

    AIR FLOW LOUVERS ADJUSTMENTS Adjusting the left and right air flow directions Move the vertical air flow louvers as illustrated, to adjust the air flow to flow towards the left or right directions. Adjusting the downward air flow direction. During the “Dehumidifying” or “Cooling” operating modes, the horizontal air flow louvers are automatically adjusted to suit the air flow angles of each operating mode.
  • Page 14: How To Exchange The Batteries In The Remote Controller

    HOW TO EXCHANGE THE BATTERIES IN THE REMOTE CONTROLLER When using the remote control, there is no response from the air conditioner unit and or the remote control has fading and dim displays, the batteries in the remote control device need to be removed and replaced with new ones Remove the cover as shown in the figure and take out the old batteries.
  • Page 15: Suitable Room Temperature

    THE IDEAL WAYS OF OPERATION Suitable Room Temperature Install curtain or blinds Warning It is possible to Freezing temperature reduce heat entering the is bad for health and a waste of electric power. room through windows. Ventilation Effective Usage Of Timer At night, please use the “OFF or ON timer Caution operation mode”, together with your wake up...
  • Page 16 FOR USER’S INFORMATION The Air Conditioner And The Heat Source In The Room Caution If the amount of heat in the room is above the cooling capability of the air conditioner (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.
  • Page 17: Attaching The Air Cleansing Filters

    ATTACHING THE AIR CLEANSING FILTERS CAUTION Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning, stop operation and switch off the power supply. Open the front panel. Pull up the front panel by holding it at both sides with both hands.
  • Page 18: Maintenance

    MAINTENANCE CAUTION Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning, stop operation and switch off the power supply. AIR FILTER Clean the air filter, as it removes dust inside the room. In case the air filter is full of dust, the air flow will decrease and the cooling capacity will be reduced.
  • Page 19: Cleaning Of Front Panel

    CLEANING OF FRONT PANEL Wipe it with a soft dry cloth. When it is excessively dirty, wipe with a soft cloth soaked in lukewarm water or neutral detergent. Then wipe thoroughly with a soft dry cloth. Wipe the remote controller thoroughly with a soft dry cloth.
  • Page 20: Regular Inspection

    CAUTION Please use earth line. Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone. Improper installation of earth line may cause electric shock. A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit breaker, the danger of electric shock exists.
  • Page 21 AFTER SALE SERVICE AND WARRANTY WHEN ASKING FOR SERVICE, CHECK THE FOLLOWING POINTS. CONDITION CHECK THE FOLLOWING POINTS Is the fuse all right? Is the voltage extremely high or low? When it does not operate Is the circuit breaker “ON”? Was the air filter cleaned? Does sunlight fall directly on the outdoor unit? Is the air flow of the outdoor unit obstructed?
  • Page 22 This product conforms with the protection requirements of council directives 89/336/EEC relating to electromagnetic compatibility and 73/23/EEC relating to electrical equipment designed for use within certain voltage limits. Please note: On switching on the equipment, particularly when the room light is dimmed, a slight brightness fluctuation may occur.

This manual is also suitable for:

Rac-s10cyRas-s13cyRas-5115cyRac-s13cyRac-5115cy

Table of Contents