Specification - Hitachi uc 18yg Handling Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5

SPECIFICATION

CHARGER
Model
Charging voltage
Weight
APPLICATION
For charging the HITACHI BATTERY.
EB712S, EB7S, FEB7S, EB714S, EB7B, EB9S, EB912S,
FEB9S, EB914S, EB914, EB9B, EB924, EB1212S,
EB12S, FEB12S, EB1214L, EB1214S, EB12B,
EB1220BL, EB1224, EB1412S, EB1414, EB1414S,
EB14B, EB1424, EB1812S, EB1814SL, EB1820,
EB1820L, EB1824L
CHARGING
Before using the power tool, charge the battery as
follows.
1. Connect the charger power cord to the receptacle
2. Insert the battery in the charger
Position the battery so that the nameplate faces
toward the nameplate of the charger and press in
the battery until it comes into contact with the
bottom plate (See Fig. 1).
Table 1 Recharging time (approx. min.) at 20°C
Battery
voltage
1.2 – 1.4 Ah
(V)
EB712S, EB7S, FEB7S,
7.2 V
EB714S
EB912S, EB9S, FEB9S,
9.6 V
EB914, EB914S
EB1212S, EB12S,
12 V
FEB12S, EB1214L,
EB1214S
EB1412S, EB1414,
14.4 V
EB1414S
18 V
EB1812S, EB1814SL
NOTE: The recharging time may vary according to the ambient temperature and the power supply voltage.
3. Disconnect the charger's power cord from the
receptacle
4. Hold the charger firmly and pull out the battery
NOTE
Be sure to pull out the battery from the charger
after use, and then keep it.
Regarding electric discharge in case of new batteries,
etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an
extended period is not activated, the electric
discharge might be low when using them the first
and second time. This is a temporary phenomenon,
Battery capacity (Ah)
2.0 Ah
EB7B
EB9B
30 min. EB12B, EB1220BL
EB14B
EB1820, EB1820L
How to make the batteries perform longer.
(1) Recharge the batteries before they become
(2) Avoid recharging at high temperatures.
UC18YG
7.2 – 18 V
0.3 kg
Inserting the battery will turn on the charger (the
pilot lamp lights up).
CAUTION
If the pilot lamp does not light up, pull out the
power cord from the receptacle and check the
battery mounting condition.
The pilot lamp goes off to indicate that the battery
is fully charged.
CAUTION
If the battery is heated due to direct sunlight,
etc., just after operation, the charger pilot lamp
may not light. At that time cool the battery first,
then start charging.
Regarding recharging time
Table 1 shows the recharging time required
according to the type of battery.
EB924
50 min. EB1224
EB1424
EB1824L
and normal time required for recharging will be
restored by recharging the batteries 2-3 times.
completely exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the
electric current, the battery may be damaged and
its life will become shorter.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
English
2.4 Ah
60 min.
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents