Installation - Carrier 42 HWS 07 Installation Manual

Table of Contents

Advertisement

42 HWS

Installation

Condensate drain pipe and refrigerant tubes.
• Fasten the electric wires and refrigerant tubes together. Allow an
additional length to the electric wires for easy connection to the unit
connectors.
• Run refrigerant tubes so the condensate drain pipe is always
positioned at the bottom of the conduit. Connect the condensate
pipe to a proper drain using a flexible PVC pipe. Horizontal runs
between indoor unit and drain orifice must have a minimum 2% slope.
Note:
Do not kink or flatten the tubes. Avoid bends with a bending radius
of less than 100 mm. Do not bend copper tubes more than three
times at the same point. Do not remove flare fittings from unit tubes
before actually making the connections. Do not fasten the insulation
too tightly to the tubes with straps or tape.
Mod. 07 - 09 - 12
Mod. 18 - 24
Attach the unit to the mounting plate by means of the upper hooks.
Refrigerant tubes of the indoor unit
Separate insulation for each tube
Electrical connecting wires
Condensate drain pipe
Template
Mod: 18 - 24
Keep the bottom end of the unit slightly away from the mounting
plate and hold this position with spacer stick
panel
and remove the electrical terminal box cover
This operation can be carried out without disassembling the
unit front panel.
Pass the electrical wires through the proper slot provided in the
back panel of the unit and pull them out in the front.
Do not make electrical connections at this stage.
Mod. 07 - 09 -12
Remove the spacer stick. To fasten the unit:
• Sizes 07, 09, 12
Slightly pull the bottom end of the unit from the wall, then push it
firmly so that the bottom hooks engage in the appropriate slots.
• Sizes 18, 24
Push the unit firmly so that the bottom hooks engage in the
appropriate slots.
Should it be necessary to detach the unit, proceed in the opposite way.
E N G L I S H
. Open the front
.
Mod. 18 - 24
GB - 7